DOI 10.7759/cureus.76369

Медицинская библиотека · Cureus · 2024

Enhancing Anemia Detection With Non-invasive Anemia Detection With AI (NiADA): Insights From Clinical Validations and Physician Observations.

Sharma Vipul, Das Debjeet, Sarkar Sagarika, Das Suvraraj, Sherpa Pasang Lahmu, Ray Arpan, Ahamed Farhad, Nandi Jhuma, Nandi Mou, Banerjee Krishanu

СтатьяПеревод пока не подготовлен

Аннотация

Background Anemia, a critical public health issue, affects nearly two billion people globally. Frequent monitoring of blood hemoglobin levels is essential for managing its burden. While point-of-care testing (POCT) devices facilitate hemoglobin testing in resource-limited settings, most are invasive and have inherent limitations. The Non-Invasive Anemia Detection App (NiADA) (Monere, UT) offers a non-invasive alternative, utilizing artificial intelligence (AI) to estimate hemoglobin levels from images of the lower eyelid. This low-cost, real-time solution employs a custom computer vision deep-learning algorithm for hemoglobin levels, offering significant potential for early diagnosis and management of anemia. Methods This study evaluated NiADA in two phases. In the first phase, its performance was compared to laboratory measurements and the minimally invasive POCT device, Hemocue Hb 301. In this study, the current version of NiADA version 2 (V2) is also compared against the previous version of NiADA version 1 (V1) to show the improvement in the last six months. In the second phase, NiADA's results were compared against hemoglobin estimations made by a group of medical professionals, as well as against lab analyzers. For both phases, NiADA performance was evaluated using the Bland-Altman plot, regression coefficients, percentage of acceptable limit, Pearson correlation coefficient, and Lin's concordance correlation coefficient. Results The mean difference between NiADA-V2 and laboratory-estimated hemoglobin values was -0.11 g/dL, with limits of agreement (LOA) ranging from +2.86 to -2.64 g/dL, where the upper limit is comparable with HemoCue. The NiADA-V2-acceptable range (percentage of samples falling within ±1 g/dL absolute error) increased to 54% compared to 40% in NiADA-V1. Additionally, NiADA outperformed medical professionals, showing a mean difference of 0.07 g/dL compared to medical professionals' 0.42 g/dL. Conclusion NiADA, as a non-invasive application, exhibits performance comparable to minimally invasive tools and other POCT devices. Its accuracy exceeds that of medical professionals, making it a viable option for anemia screening and monitoring, particularly in community medicine and regions with limited healthcare resources.

Для цитирования: Sharma Vipul, Das Debjeet, Sarkar Sagarika, Das Suvraraj, Sherpa Pasang Lahmu, Ray Arpan, Ahamed Farhad, Nandi Jhuma, Nandi Mou, Banerjee Krishanu. Enhancing Anemia Detection With Non-invasive Anemia Detection With AI (NiADA): Insights From Clinical Validations and Physician Observations.. Cureus. 2024. DOI: 10.7759/cureus.76369.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.