MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2131/jts.44.23

Медицинская библиотека · The Journal of toxicological sciences · 2019

The dermal sensitization threshold (DST) approach for mixtures evaluated as negative in in vitro test methods; mixture DST.

Nishijo Taku, Miyazawa Masaaki, Saito Kazutoshi, Otsubo Yuki, Mizumachi Hideyuki, Sakaguchi Hitoshi

СтатьяПеревод пока не подготовлен

Аннотация

Cosmetic ingredients often comprise complex mixtures, such as botanical extracts, which may contain skin sensitizing constituents. In our previous study for the sensitivity of the evaluations of skin sensitizing constituents in mixtures using the binary in vitro test battery with KeratinoSensTM and h-CLAT, some sensitizers showed higher detection limits in in vitro test methods than in murine local lymph node assays (LLNA). Thus, to minimize the uncertainty associated with decreased sensitivity for these sensitizers, a risk assessment strategy was developed for mixtures with negative results from the binary test battery. Assuming that the no expected sensitization induction level of mixtures (mixture NESIL) can be derived for mixtures with negative in vitro test results, we assessed 146 sensitizers with in vitro and LLNA data according to the assumption of indeterminate constituents in mixtures. Finally, we calculated 95th percentile probabilities of mixture NESILs and derived dermal sensitization thresholds for mixtures (mixture DST) with negative in vitro test results of 6010 μg/cm2. Feasibility studies indicated that this approach was practical for risk assessments of products in the cosmetic industry. This approach would be a novel risk assessment strategy for incorporating the DST approach and information from in vitro test methods.

Для цитирования: Nishijo Taku, Miyazawa Masaaki, Saito Kazutoshi, Otsubo Yuki, Mizumachi Hideyuki, Sakaguchi Hitoshi. The dermal sensitization threshold (DST) approach for mixtures evaluated as negative in in vitro test methods; mixture DST.. The Journal of toxicological sciences. 2019. DOI: 10.2131/jts.44.23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.