Carbon ion irradiation at a clinically used dose rewires super-enhancers to drive necroptosis and systemic immunity.

Li Chong, Liu Xueyang, Zhu Lin, Liu Ming, Konishi Teruaki, Lou Xiaokun, Chen Li, Liao Jiatao, Hong Yirui, Deng Yun, Xiao Mei, Shao Chunlin, Kong Lin, Guo Xiaomao, Su Fengtao

СтатьяПеревод пока не подготовлен

Аннотация

Radiotherapy augments immunotherapy, yet conventional 2 Gy x-ray fractions largely induce apoptosis, whereas robust immunogenic cell death (ICD) is more commonly associated with higher-dose irradiation regimens. Here, we reveal a dose-independent, high-LET-specific paradigm: a physical dose of 2 Gy of carbon ions provokes antitumor immunity. Carbon ions redirect death wiring to MLKL-dependent necroptosis and trigger an NF-κB-driven inflammatory cascade (IL1A/B, CXCL1/2/3), surpassing 8 Gy x-rays in immunogenicity despite lower direct tumor cell-killing capacity. Multi-omics analyses identify clustered DNA damage-driven super-enhancer remodeling as an epigenetic switch that suppresses cIAP1/2-caspase-8-mediated apoptosis while licensing inflammatory necroptosis. Pharmacologic inhibition of MLKL abolishes these responses to carbon ion radiotherapy (CIRT). In vivo, 2 Gy CIRT drives abscopal response with increased CD8+ T cell infiltration and function. Together, these findings establish CIRT as a feasible, immune-stimulatory radiotherapy converting local exposure into systemic control via super-enhancer-mediated reprogramming of death and inflammation, providing a mechanistic rationale to integrate carbon ions into next-generation radio-immunotherapy.

Для цитирования: Li Chong, Liu Xueyang, Zhu Lin, Liu Ming, Konishi Teruaki, Lou Xiaokun, Chen Li, Liao Jiatao, Hong Yirui, Deng Yun, Xiao Mei, Shao Chunlin, Kong Lin, Guo Xiaomao, Su Fengtao. Carbon ion irradiation at a clinically used dose rewires super-enhancers to drive necroptosis and systemic immunity.. Science advances. 2026. DOI: 10.1126/sciadv.aec7590.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.