MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40662-021-00259-x

Медицинская библиотека · Eye and vision (London, England) · 2021

Evaluation of implanted perforated lacrimal punctal plugs using anterior segment optical coherence tomography.

Abdallah Raafat Mohyeldeen Abdelrahman, Elshafei Ahmed Mohamed Kamal, AttaAllah Heba Radi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Evaluation of the patency and position of perforated lacrimal punctal plugs implanted for treating punctal stenosis together with quantitative assessment of the precorneal tear film using anterior segment optical coherence tomography (AS-OCT).

METHODS

In a prospective study, the lower punctum of 54 eyes of 29 patients implanted with perforated punctal plugs were examined using AS-OCT during the early postoperative period. Preoperative tear meniscus height (TMH) and tear meniscus area (TMA) were evaluated. Postoperatively, the patency of the plug, its position, TMH and TMA were evaluated, and the results were correlated with postoperative epiphora. Munk scale was used for epiphora grading.

RESULTS

Using AS-OCT, 48 (88.9%) plugs were found in proper position while 6 (11.1%) were rotated. The lumen of the plugs was completely patent in 47 (87%) plugs, partially obstructed in 2 (3.7%) plugs and completely occluded in 5 (9.2%) plugs. There was a statistically significant postoperative decrease of TMH and TMA (P < 0.001) and postoperative epiphora Munk score (P < 0.001).

CONCLUSION

AS-OCT is a valuable, reliable, and noninvasive investigative tool that can detect the proper positioning, patency, and contents of the implanted perforated lacrimal punctal plugs in addition to measurement of TMH and TMA. Trial registration ClinicalTrials.gov ID: NCT04624022, https://clinicaltrials.gov/ct2/show/NCT04624022.

Для цитирования: Abdallah Raafat Mohyeldeen Abdelrahman, Elshafei Ahmed Mohamed Kamal, AttaAllah Heba Radi. Evaluation of implanted perforated lacrimal punctal plugs using anterior segment optical coherence tomography.. Eye and vision (London, England). 2021. DOI: 10.1186/s40662-021-00259-x.