DOI 10.1016/j.ajo.2025.09.039

Медицинская библиотека · American journal of ophthalmology · 2025

Effectiveness and Safety of Cross-Linking in Keratoconus Patients With Corneal Thickness <400 µm: A Systematic Review and Meta-analysis.

Mohammadi Farzaneh, McGuinness Myra B, Mustafa Mohammad Zuhair, Chong Elaine W, Daniell Mark

СтатьяСистематический обзорМетаанализПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the effectiveness and safety of corneal cross-linking (CXL) in patients with keratoconus and thin corneas (corneal thickness <400 µm).

DESIGN

Systematic review and meta-analysis.

METHODS

MEDLINE Ovid, Embase Ovid, and Scopus were searched in July 2024 for studies published in peer-reviewed journals in English. Prospective and retrospective case series, cohort studies, and randomized clinical trials of people with corneal thickness of <400 µm (with or without epithelium) who underwent CXL for keratoconus were eligible, regardless of CXL approach. Key outcomes included maximum and mean corneal curvature (Kmax and Kmean), corrected and uncorrected distance visual acuity, refractive error, corneal thickness, and endothelial cell density at 3, 6, 12, and 24 months. Random effects meta-analysis was used to pool average change from preoperative values across CXL protocols. Study quality was assessed using the JBI Critical Appraisal Checklist for Case Series (PROSPERO registration: CRD42023403190).

RESULTS

A total of 29 records published between 2011 and 2024 were included with a total of 470 eyes. Most studies were retrospective case series with substantial potential for bias. Substantial heterogeneity was observed between studies in terms of patients, CXL approach, and observed outcomes. At 12 months, flattening of the maximum corneal curvature (mean change in Kmax = -1.4 D, 95% CI = - 2.0, -0.9, n = 17/402 studies/eyes, I2= 93%) and improvement in corrected distance visual acuity (mean change = -0.09 logMAR units, 95% CI = - 0.13, -0.06], n = 19/443 studies/eyes, I2= 68%) were observed relative to baseline. No study reported major complications, and there were minimal reductions in corneal thickness and endothelial cell density.

CONCLUSIONS

Visual and keratometric parameters improved following CXL without major complications, suggesting that CXL may be suitable for patients with stromal thicknesses of <400 µm, providing that adequate modifications have been applied. Prospective comparative studies are required to guide the choice of approach.

Для цитирования: Mohammadi Farzaneh, McGuinness Myra B, Mustafa Mohammad Zuhair, Chong Elaine W, Daniell Mark. Effectiveness and Safety of Cross-Linking in Keratoconus Patients With Corneal Thickness <400 µm: A Systematic Review and Meta-analysis.. American journal of ophthalmology. 2025. DOI: 10.1016/j.ajo.2025.09.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.