MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.pdpdt.2025.104783

Медицинская библиотека · Photodiagnosis and photodynamic therapy · 2025

Characteristics of corneal biomechanical parameters and corneal thickness measured by Corvis ST and AS-OCT in progressive keratoconus treated by accelerated corneal cross-linking.

Wei Luanying, Qi Tiantian, Luo Lei, Shi Qiang, Mi Shengjian, Pei Cheng

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the characteristics of corneal biomechanical parameters and corneal thickness in different corneal regions in progressive keratoconus treated by accelerated "epithelium off" cross-linking (A-CXL) surgery.

METHODS

This is a retrospective study and is self-controlled before and after surgery. A total of 39 eyes of 25 patients with progressive keratoconus were recruited and treated by A-CXL. The corneal biomechanical parameters and corneal thickness were recorded at baseline, 1-month, 3-month, and 6-month after surgery. Besides, analysis of correlations was applied to explore the association between these two features.

RESULTS

Most of the biomechanical parameters, corneal thickness of different areas, as well as visual acuity, curvature and higher-order aberrations (HOAs), showed significant changes at 1 month and 3 months after surgery. Then gradually became stable and close to baseline values at 6 months postoperative. The epithelium became thicker earlier (after 1 month). The central and inferior areas of corneal stroma and the whole cornea were significantly thinnest at 3 months, other areas were thinnest at 1 month. Only several biomechanical parameters showed positive or negative correlations with corneal thickness, including the changes of them from baseline to different time after treatment.

CONCLUSION

The accelerated cross-linking not only has a significant effect, especially on the corneal central, inferotemporal, and inferonasal regions, which can prevent the progression of keratoconus. But also, can maintain the integrity of the epithelium, achieve corneal biomechanical recovery and improve visual acuity, curvature and HOAs in the short term at the same time.

Для цитирования: Wei Luanying, Qi Tiantian, Luo Lei, Shi Qiang, Mi Shengjian, Pei Cheng. Characteristics of corneal biomechanical parameters and corneal thickness measured by Corvis ST and AS-OCT in progressive keratoconus treated by accelerated corneal cross-linking.. Photodiagnosis and photodynamic therapy. 2025. DOI: 10.1016/j.pdpdt.2025.104783.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.