DOI 10.1097/ico.0000000000003956
A Systematic Review and Meta-Analysis Comparing Epithelium-On and Epithelium-Off Corneal Collagen Cross-Linking in Keratoconus Management: Integrating New Evidence.
Аннотация
PURPOSE: Keratoconus is a progressive corneal ectasia leading to visual impairment. Corneal collagen cross-linking (CXL) is a widely used intervention to halt progression, with 2 main approaches: epithelium-on (Epi-On) and epithelium-off (Epi-Off). This study presents a meta-analysis integrating findings from existing literature and newly analyzed data.
METHODS
A systematic search was performed to compare Epi-On and Epi-Off CXL outcomes from 2014 to 2024. Meta-analysis techniques were employed to evaluate the changes in visual and imaging outcomes based on the differences between baseline to available 6-month, 1-year, 2-year, and 3-year follow-up. In addition, subgroup analyses were conducted based on study design (randomized controlled trials vs. non-RCT and observational studies) and risk of bias (high vs. low), using standardized risk assessment tools.
RESULTS
This meta-analysis included 28 studies, covering 1764 eyes including 875 (49.6%) Epi-Off and 889 (50.4%) Epi-On treated eyes. Maximum keratometry flattening was observed at 6 months (ES = 0.183, P = 0.039), became more pronounced at 1 year (ES = 0.639, P = 0.004), and remained significant at 2 years (ES = 0.377, P <0.001). Central corneal thickness significantly reduced after Epi-Off treatment at 6 months (ES = 0.327, P = 0.012) and 1 year (ES = 0.247, P = 0.040) more than Epi-on group. In addition, spherical equivalent improved significantly at 2 years (ES = -0.395, P = 0.048). In contrast, no significant differences were observed in steepest keratometry, average keratometry, best-corrected distance visual acuity, and uncorrected distance visual acuity between the 2 groups across all follow-up durations. Subgroup analysis supported the robustness of structural outcomes in Epi-Off, particularly in lower risk, observational studies and nonrandomized clinical trials, whereas functional outcomes remained not significant.
CONCLUSIONS
Epi-Off CXL demonstrates superior topographic and tomographic improvements compared with Epi-On, although visual acuity outcomes remain equivalent. These findings support a personalized approach in selecting CXL technique based on patient profile and treatment goals.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.