Atrial fibrillation detection after embolic stroke of undetermined source: Development and validation of the CATCH-AF score.
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
D'Anna Lucio, Favruzzo Francesco, Baracchini Claudio, Pes Alessandra, Mag Uidhir Fionn, Rosin Diletta, Valente Mariarosaria, Gigli Gian Luigi, Zhang Liqun, Leung Nathan, Sohal Manav, Sacco Simona, Ornello Raffaele, De Santis Federico, Coppola Ubaldo, Prandin Gabriele, Romoli Michele, Tudisco Valentina, Sepe Federica Nicoletta, Guan Jianqun, Barnard Asha, Jeffrey Lydia, Dagan Jake, Dolkar Tsering, Syed Irtiza, Banerjee Soma, Edwards Selina, Safak Ceylan, Avila Roberto, Cruz Joan, Laurie Ashley, Desai Gaurav, Haneef Maryam, Idian Anne, Chandratheva Arvind, Lim Phang Boon, Merlino Giovanni, Foschi Matteo, Simister Robert
Аннотация
METHODS: We analyzed 543 consecutive ESUS patients systematically monitored with ICMs. Variable selection used LASSO-penalized Cox regression. Model performance was assessed with time-dependent ROC curves, restricted mean survival time (RMST) analysis, and 10-fold cross-validation. To evaluate geographic generalizability, internal-external cross-validation was performed across seven participating centers, estimating discrimination and calibration for each held-out cohort. Based on the final multivariable model, a point-based score was derived including age, coronary artery disease, heart failure, and prior transient ischemic attack or ischemic stroke.
RESULTS: During 1558.5 patient-years of follow-up, 118 patients (22%) developed new AF. The CATCH-AF score showed excellent discrimination (AUC 0.85, 95% CI 0.82-0.89), stable over 4.5 years (0.84-0.87). Compared with low-risk patients (0-2 points), those at high risk (⩾5 points) had a 19-fold higher hazard of AF detection (HR 19.2, 95% CI 9.4-39.4; p < 0.001) and 918 fewer AF-free days (95% CI -1080 to -757).
CONCLUSIONS: The CATCH-AF score provides a robust, interpretable, and easily applicable tool for predicting AF after ESUS, supporting targeted and cost-effective rhythm monitoring.