Induced videokeratography alterations in patients with excessive meibomian secretions.

Markomanolakis Marinos M, Kymionis George D, Aslanides Ioannis M, Astyrakakis Nikolaos, Pallikaris Ioannis G

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe lipid-induced specific videokeratographic (VKG) corneal changes and subsequent resolution after eyelid washing.

METHODS

VKG was performed with C-Scan corneal topography. In all patients an excessive meibomian gland lipid secretion was found with or without coexistent chronic posterior blepharitis. After the initial VKG, a meticulous cleaning of the lids with a mild alkali shampoo (10% Johnson's baby shampoo in sterile water) was done, first by gently scrubbing the closed eyelid fissure with the solution to mobilize and emulsify any Meibomian gland secretions followed by cleaning of the upper and lower margins individually, using Q-tip applicators soaked in the detergent.

RESULTS

Three patients with tear film lipid layer excess (TFLE), which correlated with the presence of a superior or central corneal steepening in VKG, were studied. In two of the subjects, careful lid washing reversed either completely or partially this VKG effect, whereas in the last patient the VKG changes after artificially increasing the tear film lipid content is described.

CONCLUSIONS

Meibomian gland lipid secretions may induce mainly superior and occasionally central VKG corneal steepening that is not correlated with any slit-lamp pathologic findings. Computerized corneal topography can help detect such corneal abnormalities, and their reversibility may distinguish them from other pathologic conditions (such as contact lens-induced warpage, eccentric ablations, irregular astigmatism, superior keratoconus).

Для цитирования: Markomanolakis Marinos M, Kymionis George D, Aslanides Ioannis M, Astyrakakis Nikolaos, Pallikaris Ioannis G. Induced videokeratography alterations in patients with excessive meibomian secretions.. Cornea. 2005. DOI: 10.1097/01.ico.0000121705.40011.74.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.