DOI 10.1016/s0002-9394(03)00100-4

Медицинская библиотека · American journal of ophthalmology · 2003

Effect of phacoemulsification on corneal thickness.

Vargas Jose Manuel, McCulley James P, Bowman R Wayne, Johnston Eric W, Jani Binoy R, Shen Joanne

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the immediate effect on corneal thickness of cataract extraction using phacoemulsification.

DESIGN

Prospective consecutive nonrandomized humans undergoing standard small-incision phacoemulsification and intraocular lens insertion.

METHODS

Corneal thickness was measured immediately preoperative and postoperatively in 58 consecutive patients undergoing phacoemulsification in the absence of other ocular abnormalities. Corneal thickness was determined centrally and in the midperiphery of four quadrants. The last 17 eyes were also evaluated for the effect of pressure from a Honan balloon on corneal thickness.

SETTING

Faculty practice in medical school and university hospital. The cornea thinned in all five of the measured locations, with statistical significance being reached only in the four midperipheral quadrants. Pressure from the Honan balloon resulted in a negligible increase in corneal thickness preoperatively.

CONCLUSIONS

Corneas were found to have thinned statistically significantly immediately after phacoemulsification; however, the degree of thinning has doubtful clinical significance and does not represent a significant dehydration of the cornea during the surgical procedure.

Для цитирования: Vargas Jose Manuel, McCulley James P, Bowman R Wayne, Johnston Eric W, Jani Binoy R, Shen Joanne. Effect of phacoemulsification on corneal thickness.. American journal of ophthalmology. 2003. DOI: 10.1016/s0002-9394(03)00100-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.