MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.29309

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2020

Impact of baseline conduction abnormalities on outcomes after transcatheter aortic valve replacement with SAPIEN-3.

Sammour Yasser, Sato Kimi, Kumar Arnav, Gajulapalli Rama Dilip, Lak Hassan, Chawla Sanchit, Banerjee Kinjal, Kaur Manpreet, Patel Jay, Incognito Cameron, Svensson Lars, Popovic Zoran, Tarakji Khaldoun, Wazni Oussama, Reed Grant W, Yun James, Puri Rishi, Krishnaswamy Amar, Kapadia Samir R

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Baseline conduction abnormalities are known risk factors for permanent pacemaker (PPM) implantation after transcatheter aortic valve replacement (TAVR). We sought to determine the impact of baseline right bundle branch block (RBBB), left bundle branch block (LBBB), left anterior hemiblock (LAHB), first-degree atrioventricular block (AVB) and atrial fibrillation/flutter (AF) on TAVR outcomes.

METHODS

Consecutive patients who underwent transfemoral TAVR with SAPIEN-3 (S3) were included. We excluded patients with prior PPM, nontransfemoral access or valve-in-valve.

RESULTS

Among 886 patients, baseline RBBB was seen in 15.9%, LBBB in 6.3%, LAHB in 6.2%, first-degree AVB in 26.3% and AF in 37.5%. The rate of 30-day PPM was 10.1%. Baseline RBBB (OR 4.005; 95% CI 2.386-6.723; p < .001) and first-degree AVB (OR 1.847; 95% CI 1.133-3.009; p = .014) were independent predictors of 30 day PPM. LAHB also resulted in higher PPM rates but only in unadjusted analysis (21.8% vs. 9.4%; p = .003). Baseline LBBB and AF were associated with lower left ventricular ejection fraction (LVEF) at both baseline and 1 year after TAVR. However, Δ LVEF over time were noted to be similar with baseline LBBB (1.8% vs. 1.4%; p = .809) and AF (1.1% vs. 1.7%; p = .458). Moreover, baseline AF was also associated with higher stroke/transient ischemic attack (TIA) at 1 year (4.4% vs. 1.8%; p = .019), 1-year major adverse cardiac and cerebrovascular events (MACCE) (19.5% vs. 13.3%; p = .012) and 2 year mortality (23.5% vs. 15.2%; p = .016). None of the other baseline conduction defects affected long-term mortality or MACCE.

CONCLUSION

In our S3 TAVR population, baseline RBBB and first-degree AVB predicted higher PPM risk. Prior LBBB and AF were associated with lower LVEF at both baseline and 1 year. Lastly, preexisting AF was associated with higher rates of mortality, stroke/TIA, and MACCE.

Для цитирования: Sammour Yasser, Sato Kimi, Kumar Arnav, Gajulapalli Rama Dilip, Lak Hassan, Chawla Sanchit, Banerjee Kinjal, Kaur Manpreet, Patel Jay, Incognito Cameron, Svensson Lars, Popovic Zoran, Tarakji Khaldoun, Wazni Oussama, Reed Grant W, Yun James, Puri Rishi, Krishnaswamy Amar, Kapadia Samir R. Impact of baseline conduction abnormalities on outcomes after transcatheter aortic valve replacement with SAPIEN-3.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2020. DOI: 10.1002/ccd.29309.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.