Use of rapid cardiac magnetic resonance imaging to guide chelation therapy in patients with transfusion-dependent thalassaemia in India: UMIMI study.

Medina Katia Menacho, Abdel-Gadir Amna, Ganga Kartik, Ojha Vineeta, Pratap Surya, Boubertakh Redha, McGrath Louise, Augusto João B, Rikowski Alexander, Mughal Nabila, Khanna Virender Kumar, Seth Tulika, Sharma Sanjiv, Mahajan Amita, Bansal Rajiv K, Srivastava Prabhar, Mahajan Harsh, Mahajan Vidhur, Walker Judith, Seldon Tenzin, Ako Emmanuel, Moon James C, Walker John Malcolm

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: To explore the impact of incorporating a faster cardiac magnetic resonance (CMR) imaging protocol in a low-middle-income country (LMIC) and using the result to guide chelation in transfusion-dependent patients.

METHODS AND

RESULTS

A prospective UK-India collaborative cohort study was conducted in two cities in India. Two visits 13 months apart included clinical assessment and chelation therapy recommendations based on rapid CMR results. Participants were recruited by the local patient advocate charity, who organized the patient medical camps. The average scanning time was 11.3 ± 2.5 min at the baseline and 9.8 ± 2.4 min (P < 0.001) at follow-up. The baseline visit was attended by 103 patients (mean age 25 years) and 83% attended the second assessment. At baseline, 29% had a cardiac T2* < 20 ms, which represents significant iron loading, and 12% had left ventricular ejection fraction <60%, the accepted lower limit in this population. Only 3% were free of liver iron (T2* ≥ 17 ms). At 13 months, more patients were taking intensified dual chelation therapy (43% vs. 55%, P = 0.002). In those with cardiac siderosis (baseline T2* < 20 ms), there was an improvement in T2*-10.9 ± 5.9 to 13.5 ± 8.7 ms, P = 0.005-and fewer were classified as having clinically important cardiac iron loading (T2* < 20 ms, 24% vs. 16%, P < 0.001). This is the first illustration in an LMIC that incorporating CMR results into patient management plans can improve cardiac iron loading.

CONCLUSION

For thalassaemia patients in an LMIC, a simplified CMR protocol linked to therapeutic recommendation via the patient camp model led to enhanced chelation therapy and a reduction in cardiac iron in 1 year.

Для цитирования: Medina Katia Menacho, Abdel-Gadir Amna, Ganga Kartik, Ojha Vineeta, Pratap Surya, Boubertakh Redha, McGrath Louise, Augusto João B, Rikowski Alexander, Mughal Nabila, Khanna Virender Kumar, Seth Tulika, Sharma Sanjiv, Mahajan Amita, Bansal Rajiv K, Srivastava Prabhar, Mahajan Harsh, Mahajan Vidhur, Walker Judith, Seldon Tenzin, Ako Emmanuel, Moon James C, Walker John Malcolm. Use of rapid cardiac magnetic resonance imaging to guide chelation therapy in patients with transfusion-dependent thalassaemia in India: UMIMI study.. European heart journal. Quality of care & clinical outcomes. 2022. DOI: 10.1093/ehjqcco/qcab089.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.