MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/23258160-20160808-04

Медицинская библиотека · Ophthalmic surgery, lasers & imaging retina · 2016

Baseline Predictors of Vitreomacular Adhesion/Traction Resolution Following an Intravitreal Injection of Ocriplasmin.

Jackson Timothy L, Regillo Carl D, Girach Aniz, Dugel Pravin U, MIVI-TRUST Study Group

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

To determine factors predicting response to ocriplasmin (Jetrea; ThromboGenics, Iselin, NJ) response in patients with symptomatic vitreomacular adhesion (VMA).

PATIENTS AND

METHODS

Combined analysis of two multicenter, prospective, randomized, double-masked trials of intravitreal ocriplasmin 125 µg injection versus placebo. Patients had vitreomacular traction with or without a full-thickness macular hole (FTMH). Multivariate logistic regression was used to determine factors influencing treatment response (complete VMA release [day 28] and non-surgical FTMH closure [month 6]).

RESULTS

Younger age, presence of FTMH (odds ratio [OR] = 2.1; 95% confidence interval [CI], 1.1-3.7), VMA diameter of 1,500 µm or less (OR = 4.9; 95% CI, 2.0-12.4), phakic lens status (OR = 2.8; 95% CI, 1.5-5.2), and absence of epiretinal membrane (OR = 4.1; 95% CI, 2.2-7.9) predicted VMA resolution. FTMHs with apical diameter of 250 µm or less were more likely to close than larger holes (58.3% vs. 24.6%; P = .013). Both FTMH size groups had significantly greater chance of VMA resolution and FTMH closure versus controls.

CONCLUSION

Ocriplasmin is most effective in younger patients with focal VMA and without an epiretinal membrane. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:716-723.].

Для цитирования: Jackson Timothy L, Regillo Carl D, Girach Aniz, Dugel Pravin U, MIVI-TRUST Study Group. Baseline Predictors of Vitreomacular Adhesion/Traction Resolution Following an Intravitreal Injection of Ocriplasmin.. Ophthalmic surgery, lasers & imaging retina. 2016. DOI: 10.3928/23258160-20160808-04.