DOI 10.1016/j.jpurol.2023.11.013
The appendix conduit with a conflict of interests - An alternate strategy.
Аннотация
INTRODUCTION
Conventionally the split appendix has been used to address the need for dual conduits such as the Mitrofanoff and the ACE, however limited by its length. We present a video demonstration of an alternate solution.
MATERIAL AND
METHODS
Size-12 Nelaton catheter introduced via appendicular stump and skirted along the lateral wall of the caecum. Ethicon Endopath 35 mm Linear Stapler was used to create a caecal tube of about 3 cm based on the appendicular stump.
RESULTS
From September 2019-January 2023, 6-patients, aged 5-18 years with a diagnoses of 4-spinal dysraphisms, 1-cloacal anomaly, and 1-urogenital sinus were included.
FOLLOW UP: 5-45 months. Two patients had ACE site infection which resolved with antibiotics. One developed a stomal granuloma treated effectively with silver nitrate. All are clean with no stomal leaks and experience easy intubation.
DISCUSSION: Alternatives to the split appendix include the Monti ACE, and Caecostomy tube/caecal flap when limited by appendicular length. The technique described is easy and quick however care must be taken to keep away from the ileo-caecal junction and to keep the tube length as short as possible or needed to preserve vascularity.
CONCLUSIONS
The stapled caecal tube ACE is easy, quick, and safe especially when limited by appendicular length.