Effect of real-time computer-aided detection of colorectal adenoma in routine colonoscopy (COLO-GENIUS): a single-centre randomised controlled trial.

Karsenti David, Tharsis Gaëlle, Perrot Bastien, Cattan Philippe, Percie du Sert Alice, Venezia Franck, Zrihen Elie, Gillet Agnès, Lab Jean-Philippe, Tordjman Gilles, Cavicchi Maryan

Рандомизированное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Artificial intelligence systems have been developed to improve polyp detection. We aimed to evaluate the effect of real-time computer-aided detection (CADe) on the adenoma detection rate (ADR) in routine colonoscopy.

METHODS

This single-centre randomised controlled trial (COLO-GENIUS) was done at the Digestive Endoscopy Unit, Pôle Digestif Paris-Bercy, Clinique Paris-Bercy, Charenton-le-Pont, France. All consecutive individuals aged 18 years or older who were scheduled for a total colonoscopy and had an American Society of Anesthesiologists score of 1-3 were screened for inclusion. After the caecum was reached and the colonic preparation was appropriate, eligible participants were randomly assigned (1:1; computer-generated random numbers list) to either standard colonoscopy or CADe-assisted colonoscopy (GI Genius 2.0.2; Medtronic). Participants and cytopathologists were masked to study assignment, whereas endoscopists were not. The primary outcome was ADR, which was assessed in the modified intention-to-treat population (all randomly assigned participants except those with misplaced consent forms). Safety was analysed in all included patients. According to statistical calculations, 20 endoscopists from the Clinique Paris-Bercy had to include approximately 2100 participants with 1:1 randomisation. The trial is complete and registered with ClinicalTrials.gov, NCT04440865.

FINDINGS: Between May 1, 2021, and May 1, 2022, 2592 participants were assessed for eligibility, of whom 2039 were randomly assigned to standard colonoscopy (n=1026) or CADe-assisted colonoscopy (n=1013). 14 participants in the standard group and ten participants in the CADe group were then excluded due to misplaced consent forms, leaving 2015 participants (979 [48·6%] men and 1036 [51·4%] women) in the modified intention-to-treat analysis. ADR was 33·7% (341 of 1012 colonoscopies) in the standard group and 37·5% (376 of 1003 colonoscopies) in the CADe group (estimated mean absolute difference 4·1 percentage points [95% CI 0·0-8·1]; p=0·051). One bleeding event without deglobulisation occurred in the CADe group after a large (>2 cm) polyp resection and resolved after a haemostasis clip was placed during a second colonoscopy.

INTERPRETATION: Our findings support the benefits of CADe, even in a non-academic centre. Systematic use of CADe in routine colonoscopy should be considered.

FUNDING: None.

Для цитирования: Karsenti David, Tharsis Gaëlle, Perrot Bastien, Cattan Philippe, Percie du Sert Alice, Venezia Franck, Zrihen Elie, Gillet Agnès, Lab Jean-Philippe, Tordjman Gilles, Cavicchi Maryan. Effect of real-time computer-aided detection of colorectal adenoma in routine colonoscopy (COLO-GENIUS): a single-centre randomised controlled trial.. The lancet. Gastroenterology & hepatology. 2023. DOI: 10.1016/s2468-1253(23)00104-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.