Clinical pharmacology in drug development · 2024
Bioequivalence Between a New Omalizumab Prefilled Syringe With an Autoinjector or with a Needle Safety Device Compared with the Current Prefilled Syringe: A Randomized Controlled Trial in Healthy Volunteers.
СтатьяРандомизированное исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sangana Ramachandra, Xu Yan, Shah Bharti, Tian Xianbin, Zack Julia, Shakeri-Nejad Kasra, Kalluri Sampath, Jones Ieuan, Ligueros-Saylan Monica, Taylor Angel Fowler, Jain Devendra Kumar, Scosyrev Emil, Uddin Alkaz, Laurent Nathalie, Paganoni Paola
Аннотация
Omalizumab is an anti-IgE monoclonal antibody currently approved for the treatment of asthma, nasal polyps/chronic rhinosinusitis with nasal polyps, and chronic spontaneous urticaria. Omalizumab is available as an injection in a prefilled syringe (PFS) with a needle safety device (NSD). New product configurations were developed to reduce the number of injections per dose administration, improve patient convenience and treatment compliance. The objective of this randomized open-label 12-week study was to demonstrate pharmacokinetic bioequivalence between (1) new PFS with autoinjector (PFS-AI), (2) new PFS-NSD configuration, and (3) current PFS-NSD configuration. Each new configuration was considered bioequivalent to the current configuration if the confidence intervals (CIs) for the geometric mean ratios (GMR) were contained in the 0.80-1.25 range for maximum concentration (Cmax), area under the concentration-time curve until the last quantifiable measurement (AUClast), and AUC extrapolated to infinity (AUCinf). Safety was assessed throughout the study. In total, 193 healthy volunteers were randomized at 1:1:1 ratio to omalizumab 1×300 mg/2 mL via new PFS-AI (n = 66), omalizumab 1×300 mg/2 mL via new PFS-NSD (n = 64), or omalizumab 2×150 mg/1 mL via current PFS-NSD (n = 63). Comparing new PFS-AI versus current PFS-NSD, the GMRs were: Cmax, 1.085; AUClast, 1.093; AUCinf, 1.100. Comparing new PFS-NSD versus current PFS-NSD, the GMRs were: Cmax, 1.006; AUClast, 1.016; AUCinf, 1.027. The 95% CIs for all GMR parameters were contained within the 0.80-1.25 range. Safety findings were consistent with the known safety profile of omalizumab. Single-dose omalizumab administered as the new PFS-AI or new PFS-NSD was bioequivalent to the current PFS-NSD.