DOI 10.1097/opx.0000000000002161
Silicone hydrogel versus hydrogel soft contact lenses for differences in patient-reported eye comfort and safety: A Cochrane systematic review summary.
Аннотация
SIGNIFICANCE: This work is significant because it is the first Cochrane systemic review that compares the comfort and safety of hydrogel and silicone hydrogel soft contact lenses (SCL).
PURPOSE: This study aimed to conduct a systemic review of randomized trials comparing the comfort and safety of silicone hydrogel and hydrogel SCLs.
METHODS
CENTRAL, MEDLINE Ovid, EMBASE.com , PubMed, LILACS, ClinicalTrials.gov , and World Health Organization International Clinical Trials Registry Platform were searched on or before June 24, 2022, to identify randomized clinical trials that compared silicone hydrogel and hydrogel SCLs.
RESULTS
Seven trials were identified and evaluated. One trial reported Ocular Surface Disease Index results, with the evidence being very uncertain about the effects of SCL material on Ocular Surface Disease Index scores (mean difference, -1.20; 95% confidence interval, -10.49 to 8.09). Three trials reported visual analog scale comfort score results, with no clear difference in comfort between materials, although results were of low certainty; trial results could not be combined because the three trials reported results at different time points. None of the included trials reported Contact Lens Dry Eye Questionnaire 8 or Standard Patient Evaluation of Eye Dryness scores. There was no evidence of a clinically meaningful difference (>0.5 unit) between daily disposable silicone hydrogel and hydrogel SCLs in corneal staining, conjunctival staining, or conjunctival redness (very low certainty evidence).
CONCLUSIONS
The overall evidence for a difference between all included silicone hydrogel and hydrogel SCL trials was of very low certainty, with most trials judged as having a high overall risk of bias. There was insufficient evidence to support recommending one SCL material over the other. Future well-designed trials are needed to generate high certainty evidence to further clarify differences in SCL material comfort and safety.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.