MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jstrokecerebrovasdis.2024.107698

Медицинская библиотека · Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association · 2024

Assessment of the safety and efficacy of the Zoom 45 and 55 reperfusion catheters for medium and distal mechanical thrombectomies: A multi-institutional study.

Plute Tritan, Nayar Gautam, Weinberg Joshua, Keister Alexander, Abou-Al-Shaar Hussam, Al-Bayati Alhamza R, Nogueira Raul G, Lang Michael J, Nimjee Shahid, Gross Bradley A

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

The Zoom aspiration catheters harbor novel dimensions and construction to enhance trackability and deliverability. In addition, a beveled tip may improve thrombus interaction and aspiration force for a set inner diameter. This study evaluates their utility in medium and distal vessel occlusions.

OBJECTIVE

To evaluate the safety and efficacy of Zoom 45 and 55 aspiration catheters in medium and distal vessel thrombectomy.

METHODS

Patients treated for distal vessel occlusions via mechanical thrombectomy utilizing either the Zoom 45/55 catheter or a historical control catheter between 2021-2022 at two institutions were included in this study. Medium and distal occlusions were defined as any anterior or posterior cerebral artery branch as well as the M2-4 segment of the middle cerebral artery (MCA). Preprocedural, procedural, and postprocedural variables were obtained.

RESULTS

Thirty-eight patients underwent thrombectomy with Zoom 45 or 55 catheters; four had multiple occluded vessels. Occlusion location included the M2 in 32 cases, M3-4 in 7 cases, A2 in 2 cases and P2 in 1 case. The mean number of passes per occlusion was 1.6 and overall successful reperfusion (TICI 2b or greater) was achieved in 84 % of cases. There were no symptomatic procedure-related complications such as perforation or post-procedural symptomatic ICH. Modified Rankin scores rates of 0-2, 3-5, and 6 at three months post-procedure were 35.7 %, 21.4 %, and 42.9 %, respectively.

CONCLUSIONS

The Zoom beveled tip aspiration catheters are safe and effective for more challenging medium and distal vessel occlusions.

Для цитирования: Plute Tritan, Nayar Gautam, Weinberg Joshua, Keister Alexander, Abou-Al-Shaar Hussam, Al-Bayati Alhamza R, Nogueira Raul G, Lang Michael J, Nimjee Shahid, Gross Bradley A. Assessment of the safety and efficacy of the Zoom 45 and 55 reperfusion catheters for medium and distal mechanical thrombectomies: A multi-institutional study.. Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association. 2024. DOI: 10.1016/j.jstrokecerebrovasdis.2024.107698.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.