MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2025.102572

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2025

Tear molecule concentrations as potential biomarkers of digital eye strain.

Redondo Beatriz, Lara-Vázquez Paula M, Vera Jesús, Rosenfield Mark

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The objective of this study was to investigate differences in tear inflammatory molecules after digital and paper-based reading, examine the influence of cognitive load and explore their relationship with digital eye strain (DES) symptoms.

METHODS

Twenty-four young adults completed four 30-minute reading tasks, each varying in cognitive demands (high vs. low) and reading media (digital vs. paper). After each task, unstimulated tear samples were collected and analyzed using multiplex bead assays to quantify the concentrations of 12 tear molecules. Participants also completed a questionnaire to assess visual symptomatology.

RESULTS

Reading from a digital screen significantly increased tear concentrations of IL-1α (P = 0.02), IL-6 (P = 0.03), IL-8 (P = 0.004), TGF-α (P = 0.02), and TNF-β (P = 0.01) compared to reading printed text. High cognitive load was also associated with elevated IL-8 (P = 0.002) and TNF-β (P = 0.02) levels. Participants reported higher visual discomfort when using digital screens, with higher cognitive demand exacerbating these symptoms. Correlation analyses revealed moderate positive relationships between the changes induced by the display type on IL-1α and DES symptoms (P = 0.02), and between IL and 6 (P = 0.02), TGF-α (P = 0.04) and TNF-β (P = 0.05) with cognitive load-induced discomfort. A subgroup analysis based on dry eye symptomatology revealed that individuals with fewer symptoms exhibited higher cytokine concentrations for IL-1α (P = 0.05) and TGF-α (P = 0.02).

CONCLUSIONS

Tear biomarkers could serve as objective tools for evaluating DES, offering a deeper understanding of the physiological mechanisms involved in the condition.

Для цитирования: Redondo Beatriz, Lara-Vázquez Paula M, Vera Jesús, Rosenfield Mark. Tear molecule concentrations as potential biomarkers of digital eye strain.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2025. DOI: 10.1016/j.clae.2025.102572.