Machine Learning for Myocardial Infarction Compared With Guideline-Recommended Diagnostic Pathways.

Boeddinghaus Jasper, Doudesis Dimitrios, Lopez-Ayala Pedro, Lee Kuan Ken, Koechlin Luca, Wildi Karin, Nestelberger Thomas, Borer Raphael, Miró Òscar, Martin-Sanchez F Javier, Strebel Ivo, Rubini Giménez Maria, Keller Dagmar I, Christ Michael, Bularga Anda, Li Ziwen, Ferry Amy V, Tuck Chris, Anand Atul, Gray Alasdair, Mills Nicholas L, Mueller Christian, CoDE-ACS and APACE Investigators

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Collaboration for the Diagnosis and Evaluation of Acute Coronary Syndrome (CoDE-ACS) is a validated clinical decision support tool that uses machine learning with or without serial cardiac troponin measurements at a flexible time point to calculate the probability of myocardial infarction (MI). How CoDE-ACS performs at different time points for serial measurement and compares with guideline-recommended diagnostic pathways that rely on fixed thresholds and time points is uncertain.

METHODS

Patients with possible MI without ST-segment-elevation were enrolled at 12 sites in 5 countries and underwent serial high-sensitivity cardiac troponin I concentration measurement at 0, 1, and 2 hours. Diagnostic performance of the CoDE-ACS model at each time point was determined for index type 1 MI and the effectiveness of previously validated low- and high-probability scores compared with guideline-recommended European Society of Cardiology (ESC) 0/1-hour, ESC 0/2-hour, and High-STEACS (High-Sensitivity Troponin in the Evaluation of Patients With Suspected Acute Coronary Syndrome) pathways.

RESULTS

In total, 4105 patients (mean age, 61 years [interquartile range, 50-74]; 32% women) were included, among whom 575 (14%) had type 1 MI. At presentation, CoDE-ACS identified 56% of patients as low probability, with a negative predictive value and sensitivity of 99.7% (95% CI, 99.5%-99.9%) and 99.0% (98.6%-99.2%), ruling out more patients than the ESC 0-hour and High-STEACS (25% and 35%) pathways. Incorporating a second cardiac troponin measurement, CoDE-ACS identified 65% or 68% of patients as low probability at 1 or 2 hours, for an identical negative predictive value of 99.7% (99.5%-99.9%); 19% or 18% as high probability, with a positive predictive value of 64.9% (63.5%-66.4%) and 68.8% (67.3%-70.1%); and 16% or 14% as intermediate probability. In comparison, after serial measurements, the ESC 0/1-hour, ESC 0/2-hour, and High-STEACS pathways identified 49%, 53%, and 71% of patients as low risk, with a negative predictive value of 100% (99.9%-100%), 100% (99.9%-100%), and 99.7% (99.5%-99.8%); and 20%, 19%, or 29% as high risk, with a positive predictive value of 61.5% (60.0%-63.0%), 65.8% (64.3%-67.2%), and 48.3% (46.8%-49.8%), resulting in 31%, 28%, or 0%, who require further observation in the emergency department, respectively.

CONCLUSIONS

CoDE-ACS performs consistently irrespective of the timing of serial cardiac troponin measurement, identifying more patients as low probability with comparable performance to guideline-recommended pathways for MI. Whether care guided by probabilities can improve the early diagnosis of MI requires prospective evaluation.

REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00470587.

Для цитирования: Boeddinghaus Jasper, Doudesis Dimitrios, Lopez-Ayala Pedro, Lee Kuan Ken, Koechlin Luca, Wildi Karin, Nestelberger Thomas, Borer Raphael, Miró Òscar, Martin-Sanchez F Javier, Strebel Ivo, Rubini Giménez Maria, Keller Dagmar I, Christ Michael, Bularga Anda, Li Ziwen, Ferry Amy V, Tuck Chris, Anand Atul, Gray Alasdair, Mills Nicholas L, Mueller Christian, CoDE-ACS and APACE Investigators. Machine Learning for Myocardial Infarction Compared With Guideline-Recommended Diagnostic Pathways.. Circulation. 2024. DOI: 10.1161/circulationaha.123.066917.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.