MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/xst-210898

Медицинская библиотека · Journal of X-ray science and technology · 2021

Higher agreement in endovascular treatment decision-making than in parametric quantifications among automated CT perfusion software packages in acute ischemic stroke.

Pérez-Pelegrí Manuel, Biarnés Carles, Thió-Henestrosa Santiago, Remollo Sebastià, Gimeno Alfredo, Cuba Víctor, Teceño Mikel, Martí-Navas Marian, Serena Joaquín, Pedraza Salvador, Ruiz-Constantino Juan Sebastián, Puig Josep

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

Estimates of parameters used to select patients for endovascular thrombectomy (EVT) for acute ischemic stroke differ among software packages for automated computed tomography (CT) perfusion analysis. To determine impact of these differences in decision making, we analyzed intra-observer and inter-observer agreement in recommendations about whether to perform EVT based on perfusion maps from 4 packages.

METHODS

Perfusion CT datasets from 63 consecutive patients with suspected acute ischemic stroke were retrospectively postprocessed with 4 packages of Minerva, RAPID, Olea, and IntelliSpace Portal (ISP). We used Pearson correlation coefficients and Bland-Altman analysis to compare volumes of infarct core, penumbra, and mismatch calculated by Minerva and RAPID. We used kappa analysis to assess agreement among decisions of 3 radiologists about whether to recommend EVT based on maps generated by 4 packages.

RESULTS

We found significant differences between using Minerva and RAPID to estimate penumbra (67.39±41.37mL vs. 78.35±45.38 mL, p < 0.001) and mismatch (48.41±32.03 vs. 61.27±32.73mL, p < 0.001), but not of infarct core (p = 0.230). Pearson correlation coefficients were 0.94 (95%CI:0.90-0.96) for infarct core, 0.87 (95%CI:0.79-0.91) for penumbra, and 0.72 (95%CI:0.57-0.83) for mismatch volumes (p < 0.001). Limits of agreements were (-21.22-25.02) for infarct core volumes, (-54.79-32.88) for penumbra volumes, and (-60.16-34.45) for mismatch volumes. Final agreement for EVT decision-making was substantial between Minerva vs. RAPID (k = 0.722), Minerva vs. Olea (k = 0.761), and RAPID vs. Olea (k = 0.782), but moderate for ISP vs. the other three.

CONCLUSIONS

Despite quantitative differences in estimates of infarct core, penumbra, and mismatch using 4 software packages, their impact on radiologists' decisions about EVT is relatively small.

Для цитирования: Pérez-Pelegrí Manuel, Biarnés Carles, Thió-Henestrosa Santiago, Remollo Sebastià, Gimeno Alfredo, Cuba Víctor, Teceño Mikel, Martí-Navas Marian, Serena Joaquín, Pedraza Salvador, Ruiz-Constantino Juan Sebastián, Puig Josep. Higher agreement in endovascular treatment decision-making than in parametric quantifications among automated CT perfusion software packages in acute ischemic stroke.. Journal of X-ray science and technology. 2021. DOI: 10.3233/xst-210898.