MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/00015385.2019.1700336

Медицинская библиотека · Acta cardiologica · 2019

Clinical significance of 12 lead ECG changes in patients undergoing pericardiocentesis for cardiac tamponade.

Chandra Avinash, Marhefka Gregary D, DeCaro Matthew V

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The electrocardiogram (ECG) is one of the initial tests done in patients suspected of having a cardiac Tamponade. Historically the emphasis has been on low QRS voltage and electrical alternans, which lacks specificity and sensitivity respectively. Majority of these studies included patients with pericardial effusions without tamponade. Moreover, the influence of different therapeutic interventions such as pericardiocentesis on ECG variables has not been elucidated.

OBJECTIVE

To determine the clinical significance of 12 lead ECG changes in patients undergoing pericardiocentesis for cardiac tamponade.

METHODS

144 patients underwent Echo guided pericardiocentesis for cardiac tamponade at a tertiary care hospital over a period of 7 years. We compared 19 EKG variables pre and post procedure.

RESULTS

Low voltage was detected in only 31 patients (29%) with 19 (18%) patients having persistent low voltage (p value = 0.0047) after the pericardiocentesis. Electrical alternans was only observed in 25 patients (23%), and persisted in 10 patients (10%) following pericardiocentesis. None of the other EKG variables measured changed reliably post procedure.

CONCLUSION

We found that although electrical alternans and low voltage were associated with cardiac tamponade, none of the ECG variables were highly sensitive or specific for the diagnosis, reproducibly changed after drainage or predicted recurrent effusion post-pericardiocentesis.

Для цитирования: Chandra Avinash, Marhefka Gregary D, DeCaro Matthew V. Clinical significance of 12 lead ECG changes in patients undergoing pericardiocentesis for cardiac tamponade.. Acta cardiologica. 2019. DOI: 10.1080/00015385.2019.1700336.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.