MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12871-023-01976-7

Медицинская библиотека · BMC anesthesiology · 2023

Changes of cardiac output and velocity time integral in blood return at the end of renal replacement therapy predict fluid responsiveness in critically Ill patients with acute circulatory failure.

Huang Daozheng, Ma Jie, Wang Shouhong, Qin Tiehe, Song Feier, Hou Tieying, Ma Huan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To observe if blood return, also defined as the blood infusion test (BIT) could predict fluid responsiveness in critically ill patients with acute circulatory failure and renal replacement therapy (RRT).

METHODS

This was a single-center, prospective, diagnostic accuracy study. Before BIT, the passive leg raise test (PLRT) was performed to record the change of cardiac output (ΔCO) by pulse contour analysis, and ΔCO >  = 10% was defined as the fluid responder. Meanwhile, the change in velocity time integral (ΔVTI) was recorded by ultrasound. Later, the ΔCO and ΔVTI during BIT were recorded 5-10 min after PLRT. The receiver-operating characteristic curves of ΔCO and ΔVTI of BIT were performed in predicting the fluid responder defined by PLRT.

RESULTS

A total of 43 patients with acute circulatory failure undergoing RRT were enrolled in the present study, and 25 patients (58.1%) were recognized as responders during PLRT. According to the receiver-operating characteristic curves, the cutoff value of ΔCO was 10% and ΔVTI was 9% during BIT with the area under curve of 0.96 and 0.94, respectively.

CONCLUSIONS

BIT in RRT could identify fluid responsiveness in critically ill patients with shock.

TRIAL REGISTRATION: ChiCTR-DDD-17010534. Registered on 30/01/2017 (retrospective registration).

Для цитирования: Huang Daozheng, Ma Jie, Wang Shouhong, Qin Tiehe, Song Feier, Hou Tieying, Ma Huan. Changes of cardiac output and velocity time integral in blood return at the end of renal replacement therapy predict fluid responsiveness in critically Ill patients with acute circulatory failure.. BMC anesthesiology. 2023. DOI: 10.1186/s12871-023-01976-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.