Comparison of the Outcome of Patients Protected by the Wearable Cardioverter Defibrillator (WCD) for <90 Wear Days versus ≥90 Wear Days.

Dreher Tobias C, El-Battrawy Ibrahim, RÖger Susanne, Rosenkaimer Stephanie L, Gerhards Stefan, Kuschyk JÜrgen, Borggrefe Martin, Akin Ibrahim

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIM: The wearable cardioverter/defibrillator (WCD) is recommended to prevent sudden cardiac death (SCD). Guidelines suggest a 90 days' period, but prolongation of WCD wear time until increasing the ejection fraction (≥35%) might be suggested.

PATIENTS AND

METHODS

A cohort of 153 patients with prescribed WCD were divided into two groups: A <90 wear days' group (n=112) vs. ≥90 wear days' group (n=41) and followed.

RESULTS

In the first group, WCD shock occurred in 3.6% of patients, 47.3% improved in left ventricular ejection fraction (LVEF) after 3 months, and 37.5% had a cardiac implantable electronic device (CIED) implantation with appropriate implantable cardioverter defibrillator (ICD) shock events occurring in 6 patients. Two of these patients already received WCD shock therapy due to ventricular fibrillation. A 20.5% improved in LVEF after 6-12 months, but 73% were already implanted with ICD. In the second group, 4.9% received WCD shock, 34.1% improved in LVEF after 3 months, 48.8% were implanted with ICD, and 2 had ICD shocks during follow up time. LVEF improvement after 6-12 months occurred in 26.8%. ICD implantation was prevented in 7.3% of patients due to LVEF recovery.

CONCLUSION

Prolonging wearing days of WCD may reduce the number of inappropriate ICD implantation.

Для цитирования: Dreher Tobias C, El-Battrawy Ibrahim, RÖger Susanne, Rosenkaimer Stephanie L, Gerhards Stefan, Kuschyk JÜrgen, Borggrefe Martin, Akin Ibrahim. Comparison of the Outcome of Patients Protected by the Wearable Cardioverter Defibrillator (WCD) for <90 Wear Days versus ≥90 Wear Days.. In vivo (Athens, Greece). 2020. DOI: 10.21873/invivo.12205.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.