Le Xuan Hoang, Lin Chin Yu, Chung Fa Po, Lin Yenn Jiang, Chang Shih Lin, Lo Li Wei, Hu Yu Feng, Tuan Ta Chuan, Chao Tze Fan, Liao Jo Nan, Li Guan Yi, Chang Ting Yung, Kuo Ling, Wu Cheng I, Liu Chih Min, Liu Shin Huei, Kuo Ming Jen, Huang Yu-Shan, Ling Lo Chieh, Chan Cheng Han, Chang Da Wei, Nguyen Minh Nhut, Bromeo Paula Victoria Catherine Cheng, Chen Shih Ann

СтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Premature ventricular contractions (PVCs) originating from the proximal left anterior fascicle (LAF) are rarely discussed. We aimed to describe the characteristics and ablation outcome of PVCs originating from the proximal LAF and propose a stepwise approach.

METHOD AND

RESULTS

From 2018 to 2024, 16 patients (nine males) with proximal LAF-PVCs who underwent ablation were enrolled, and their electrophysiological characteristics and procedural details were analyzed. The acute procedural outcomes were complete success, success with residual nonclinical PVCs, and partial success (decrease in clinical PVCs). The electrocardiographs of the PVCs showed a right bundle branch block with an inferior axis. In the initial ablation attempt, targeting the earliest left ventricular (LV) endocardial activation site eliminated clinical PVC in 14 patients. Nonclinical PVC occurred in seven patients. A second attempt from the right coronary cusp (RCC) was made in four patients (three nonclinical and one clinical PVC), which resulted in complete success. One patient (6.3%, partial success) had PVC recurrence. Sites with a successful ablation showed a significantly greater Fascicle-QRS[PVC] interval, Delta Fascicle-QRS[PVC-Sinus] interval, and more reverse fascicle potentials than other sites. Patients who underwent successful supra-RCC ablation had a shorter RCC-LV earliest activation site distance (EAS).

CONCLUSION

This is the first study to investigate the dynamic electrogram property in LAF-PVC ablation. The Fascicle-PVC interval and reverse fascicle are useful for predicting acute ablation success. The RCC approach may be effective in cases with a short RCC-LV EAS distance. Nonclinical PVC morphology could be due to LAF block and might not affect the long-term outcome after careful mapping.

Для цитирования: Le Xuan Hoang, Lin Chin Yu, Chung Fa Po, Lin Yenn Jiang, Chang Shih Lin, Lo Li Wei, Hu Yu Feng, Tuan Ta Chuan, Chao Tze Fan, Liao Jo Nan, Li Guan Yi, Chang Ting Yung, Kuo Ling, Wu Cheng I, Liu Chih Min, Liu Shin Huei, Kuo Ming Jen, Huang Yu-Shan, Ling Lo Chieh, Chan Cheng Han, Chang Da Wei, Nguyen Minh Nhut, Bromeo Paula Victoria Catherine Cheng, Chen Shih Ann. Premature Ventricular Contractions From the Proximal Left Anterior Fascicle: Insight From the Electrophysiologic and Anatomic Parameters.. Journal of cardiovascular electrophysiology. 2025. DOI: 10.1111/jce.70164.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.