Buckley T, Dudley S M, Donowitz L G
Аннотация
BACKGROUND: Recommendations in the literature conflict on the necessity of disinfecting single-use vials prior to aspiration of fluid. Interventions to disinfect the stopper surface on multiple-dose vials vary considerably.
OBJECTIVES: To determine the necessity of alcohol disinfection of the stopper on single-dose vials and to compare povidone-iodine and alcohol versus alcohol-only disinfection of the stopper prior to each needle penetration on multiple-dose vials.
METHODS: The rubber stopper surfaces of 100 single-dose vials were cultured for the presence of bacteria. To determine the efficacy of two procedures for disinfection of multiple-dose vials, 87 stopper surfaces routinely disinfected with both povidone-iodine and alcohol were cultured for bacteria. After a change in practice, 100 multiple-dose vials routinely disinfected with alcohol only were cultured for the presence of bacteria.
RESULTS: Of the cultures done on single-dose vial stoppers, 99% were sterile. A comparison of the two disinfection techniques for multiple-dose vials revealed that 83 (95%) of the 87 vials prepped with both povidone-iodine and alcohol were sterile, compared with all stoppers disinfected with alcohol only.
CONCLUSIONS: This study shows the lack of necessity of any disinfection procedure on the rubber stopper of single-dose vials and the efficacy of alcohol only for disinfecting the stopper of multiple-dose vials.
OBJECTIVES: To determine the necessity of alcohol disinfection of the stopper on single-dose vials and to compare povidone-iodine and alcohol versus alcohol-only disinfection of the stopper prior to each needle penetration on multiple-dose vials.
METHODS: The rubber stopper surfaces of 100 single-dose vials were cultured for the presence of bacteria. To determine the efficacy of two procedures for disinfection of multiple-dose vials, 87 stopper surfaces routinely disinfected with both povidone-iodine and alcohol were cultured for bacteria. After a change in practice, 100 multiple-dose vials routinely disinfected with alcohol only were cultured for the presence of bacteria.
RESULTS: Of the cultures done on single-dose vial stoppers, 99% were sterile. A comparison of the two disinfection techniques for multiple-dose vials revealed that 83 (95%) of the 87 vials prepped with both povidone-iodine and alcohol were sterile, compared with all stoppers disinfected with alcohol only.
CONCLUSIONS: This study shows the lack of necessity of any disinfection procedure on the rubber stopper of single-dose vials and the efficacy of alcohol only for disinfecting the stopper of multiple-dose vials.