On the accuracy of image registration in portable low-field 3D brain MRI.

Iglesias J Eugenio, Johnson Ian P, Williams-Ramirez Jonathan, Zemlyanker Dina, Tian Lin, Gopinath Karthik, Olchanyi Mark, Farnan Ava D, Demopoulos Amelia, Rosen Matthew S, Sheth Kevin N, de Havenon Adam, Kimberly W Taylor, Sorby-Adams Annabel, Alzheimer’s Disease Neuroimaging Initiative (ADNI)9

СтатьяПрепринтПеревод пока не подготовлен

Аннотация

Portable low-field MRI offers an affordable and mobile alternative to conventional high-field scanners, enabling imaging in point-of-care and resource-limited settings. However, its lower signal-to-noise ratio, reduced resolution, and acquisition artifacts raise concerns about the accuracy of standard image registration methods. Reliable registration is critical for a wide range of emerging applications, including frequent brain monitoring, assessment of neurodegenerative disease progression, and evaluation of treatment effects such as those of Alzheimer's therapeutics. In this work, we systematically evaluated state-of-the-art registration approaches on simulated low-field scans (obtained by downsampling high-field images) and on real low-field brain MRI data. We compared three representative approaches: classical optimization (NiftyReg), learning-based registration (SynthMorph), and synthesis-based registration (SynthSR+NiftyReg). Using downsampled high-field scans, all methods performed well, achieving high Dice scores and smooth deformation fields, indicating that reduced resolution alone does not hinder registration. In contrast, real low-field data exhibited lower accuracy, primarily due to geometric distortion and other acquisition-specific artifacts. Among the tested approaches, the synthesis-based pipeline achieved the most robust performance across subjects and modalities. Overall, existing algorithms can accommodate resolution limitations, however, future methods could further enhance coregistration by explicitly addressing the distortions present in low-field MRI scans.

Для цитирования: Iglesias J Eugenio, Johnson Ian P, Williams-Ramirez Jonathan, Zemlyanker Dina, Tian Lin, Gopinath Karthik, Olchanyi Mark, Farnan Ava D, Demopoulos Amelia, Rosen Matthew S, Sheth Kevin N, de Havenon Adam, Kimberly W Taylor, Sorby-Adams Annabel, Alzheimer’s Disease Neuroimaging Initiative (ADNI)9. On the accuracy of image registration in portable low-field 3D brain MRI.. bioRxiv : the preprint server for biology. 2026. DOI: 10.64898/2026.02.11.705413.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.