DOI 10.1590/1518-8345.7589.4795
Failure mode and effect analysis in the indwelling urinary catheterization process.
Аннотация
to analyze potential risks in the adult indwelling urinary catheterization process. exploratory, descriptive and evaluative research in a teaching hospital. Working group with ten health care providers: eight nurses, one physician and one nursing technician. Activity flowchart and description built through process modeling. Potential risk analysis based on the Failure Mode and Effect Analysis method. four sub-processes identified for the indwelling urinary catheterization process. Process review-based proactive health care risk analysis showed 55 potential failure modes, 92 potential failure causes, and 40 potential failure effects. the method applied to review the indwelling urinary catheterization process in the hospital setting supported the proactive health care risk analysis; this issue should be further considered to contribute to the safety culture at the national level. Nurses are strategic in decision-making on health care risk management in said process, throughout catheter introduction, continuous use, and removal.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.