The Updated Registry of Fast Myocardial Perfusion Imaging with Next-Generation SPECT (REFINE SPECT 2.0).

Miller Robert J H, Lemley Mark, Shanbhag Aakash, Ramirez Giselle, Liang Joanna X, Builoff Valerie, Kavanagh Paul, Sharir Tali, Hauser M Timothy, Ruddy Terrence D, Fish Mathews B, Bateman Timothy M, Acampa Wanda, Einstein Andrew J, Dorbala Sharmila, Di Carli Marcelo F, Feher Attila, Miller Edward J, Sinusas Albert J, Halcox Julian, Martins Monica, Kaufmann Philipp A, Dey Damini, Berman Daniel S, Slomka Piotr J

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

The Registry of Fast Myocardial Perfusion Imaging with Next-Generation SPECT (REFINE SPECT) has been expanded to include more patients and CT attenuation correction imaging. We present the design and initial results from the updated registry.

Methods

The updated REFINE SPECT is a multicenter, international registry with clinical data and image files. SPECT images were processed by quantitative software and CT images by deep learning software detecting coronary artery calcium (CAC). Patients were followed for major adverse cardiovascular events (MACEs) (death, myocardial infarction, unstable angina, late revascularization).

Results

The registry included scans from 45,252 patients from 13 centers (55.9% male, 64.7 ± 11.8 y). Correlating invasive coronary angiography was available for 3,786 (8.4%) patients. CT attenuation correction imaging was available for 13,405 patients. MACEs occurred in 6,514 (14.4%) patients during a median follow-up of 3.6 y (interquartile range, 2.5-4.8 y). Patients with a stress total perfusion deficit of 5% to less than 10% (unadjusted hazard ratio [HR], 2.42; 95% CI, 2.23-2.62) and a stress total perfusion deficit of at least 10% (unadjusted HR, 3.85; 95% CI, 3.56-4.16) were more likely to experience MACEs. Patients with a deep learning CAC score of 101-400 (unadjusted HR, 3.09; 95% CI, 2.57-3.72) and a CAC of more than 400 (unadjusted HR, 5.17; 95% CI, 4.41-6.05) were at increased risk of MACEs.

Conclusion

The REFINE SPECT registry contains a comprehensive set of imaging and clinical variables. It will aid in understanding the value of SPECT myocardial perfusion imaging, leverage hybrid imaging, and facilitate validation of new artificial intelligence tools for improving prediction of adverse outcomes incorporating multimodality imaging.

Для цитирования: Miller Robert J H, Lemley Mark, Shanbhag Aakash, Ramirez Giselle, Liang Joanna X, Builoff Valerie, Kavanagh Paul, Sharir Tali, Hauser M Timothy, Ruddy Terrence D, Fish Mathews B, Bateman Timothy M, Acampa Wanda, Einstein Andrew J, Dorbala Sharmila, Di Carli Marcelo F, Feher Attila, Miller Edward J, Sinusas Albert J, Halcox Julian, Martins Monica, Kaufmann Philipp A, Dey Damini, Berman Daniel S, Slomka Piotr J. The Updated Registry of Fast Myocardial Perfusion Imaging with Next-Generation SPECT (REFINE SPECT 2.0).. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2024. DOI: 10.2967/jnumed.124.268292.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.