Optimizing Positive End-Expiratory Pressure Based on Intra-Abdominal Pressure in Patients with Acute Respiratory Failure.
Аннотация
BACKGROUND
Positive end-expiratory pressure (PEEP) is a crucial component of mechanical ventilation to improve oxygenation in critically ill patients with respiratory failure. The interaction between abdominal and thoracic compartment pressures is known well. Especially in intra-abdominal hypertension, lower PEEP may cause atelectotrauma by repetitive opening and closing of alveoli.
AIM: In this study, it was aimed to investigate the effect of PEEP adjustment according to the intra-abdominal pressure (IAP) on oxygenation and clarify possible harms.
METHOD: Patients older than 18 were mechanically ventilated due to hypoxemic respiratory failure and had normal IAP (<15 mmHg) included in the study. Patients with severe cardiovascular dysfunction were excluded. The following PEEP levels were applied: PEEPzero of 0 cmH2O, PEEPIAP/2 = 50% of IAP, and PEEPIAP = 100% of IAP. After a 30-minute equilibration period, arterial blood gases and mean arterial pressures were measured.
RESULTS
One hundred thirty-eight patients (mean age 66.5 ± 15.9, 56.5% male) enrolled on the study. The mean IAP was 9.8 ± 3.4. Seventy-nine percent of the patients' PaO2/FiO2 ratio was under 300 mmHg. Figure 1 shows the change in PaO2/FiO2 ratio, PaCO2, PPlato, and MAP of the patients according to the PEEP levels. Overall increases were detected in the PaO2/FiO2 ratio (P < 0.001) and Pplato (P < 0.001), while PaCO2 and MAP did not change after increasing PEEP gradually. Pairwise analyses revealed differences in PaO2/FiO2 between PEEPzero (186.4 [85.7-265.8]) and PEEPIAP/2 (207.7 [101.7-292.9]) (t = -0.77, P < 0.001), between baseline and PEEPIAP (236.1 [121.4-351.0]) (t = -1.7, P < 0.001), and between PEEPIAP/2 and PEEPIAP (t = -1.0, P < 0.001). Plato pressures were in the safe range (<30 cmH2O) at all three PEEP levels (PEEPzero = 12 [10-15], PEEPIAP/2 = 15 [13-18], PEEPIAP = 17 [14-22]).
CONCLUSION
In patients with acute hypoxemic respiratory failure and mechanically ventilated, PEEP adjustment according to the IAB improves oxygenation, especially in the settings of the limited source where other PEEP titration methods are absent.