MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/cce.0000000000001059

Медицинская библиотека · Critical care explorations · 2024

Racial Differences in Accuracy of Predictive Models for High-Flow Nasal Cannula Failure in COVID-19.

Yang Philip, Gregory Ismail A, Robichaux Chad, Holder Andre L, Martin Greg S, Esper Annette M, Kamaleswaran Rishikesan, Gichoya Judy W, Bhavani Sivasubramanium V

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To develop and validate machine learning (ML) models to predict high-flow nasal cannula (HFNC) failure in COVID-19, compare their performance to the respiratory rate-oxygenation (ROX) index, and evaluate model accuracy by self-reported race.

DESIGN

Retrospective cohort study.

SETTING

Four Emory University Hospitals in Atlanta, GA.

PATIENTS: Adult patients hospitalized with COVID-19 between March 2020 and April 2022 who received HFNC therapy within 24 hours of ICU admission were included.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN

RESULTS

Four types of supervised ML models were developed for predicting HFNC failure (defined as intubation or death within 7 d of HFNC initiation), using routine clinical variables from the first 24 hours of ICU admission. Models were trained on the first 60% (n = 594) of admissions and validated on the latter 40% (n = 390) of admissions to simulate prospective implementation. Among 984 patients included, 317 patients (32.2%) developed HFNC failure. eXtreme Gradient Boosting (XGB) model had the highest area under the receiver-operator characteristic curve (AUROC) for predicting HFNC failure (0.707), and was the only model with significantly better performance than the ROX index (AUROC 0.616). XGB model had significantly worse performance in Black patients compared with White patients (AUROC 0.663 vs. 0.808, p = 0.02). Racial differences in the XGB model were reduced and no longer statistically significant when restricted to patients with nonmissing arterial blood gas data, and when XGB model was developed to predict mortality (rather than the composite outcome of failure, which could be influenced by biased clinical decisions for intubation).

CONCLUSIONS

Our XGB model had better discrimination for predicting HFNC failure in COVID-19 than the ROX index, but had racial differences in accuracy of predictions. Further studies are needed to understand and mitigate potential sources of biases in clinical ML models and to improve their equitability.

Для цитирования: Yang Philip, Gregory Ismail A, Robichaux Chad, Holder Andre L, Martin Greg S, Esper Annette M, Kamaleswaran Rishikesan, Gichoya Judy W, Bhavani Sivasubramanium V. Racial Differences in Accuracy of Predictive Models for High-Flow Nasal Cannula Failure in COVID-19.. Critical care explorations. 2024. DOI: 10.1097/cce.0000000000001059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.