m+Medelevator.RU
← Поиск публикаций
Biosensors · 2025

Evaluating Normalization Methods for Robust Spectral Performance Assessments of Hyperspectral Imaging Cameras.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mazdeyasna Siavash, Arefin Mohammed Shahriar, Fales Andrew, Leavesley Silas J, Pfefer T Joshua, Wang Quanzeng

Аннотация

Hyperspectral imaging (HSI) technology, which offers both spatial and spectral information, holds significant potential for enhancing diagnostic performance during endoscopy and other medical procedures. However, quantitative evaluation of HSI cameras is challenging due to various influencing factors (e.g., light sources, working distance, and illumination angle) that can alter the reflectance spectra of the same target as these factors vary. Towards robust, universal test methods, we evaluated several data normalization methods aimed at minimizing the impact of these factors. Using a high-resolution HSI camera, we measured the reflectance spectra of diffuse reflectance targets illuminated by two different light sources. These spectra, along with the reference spectra from the target manufacturer, were normalized with nine different methods (e.g., area under the curve, standard normal variate, and centering power methods), followed by a uniform scaling step. We then compared the measured spectra to the reference to evaluate the capability of each normalization method in ensuring a consistent, standardized performance evaluation. Our results demonstrate that normalization can mitigate the impact of some factors during HSI camera evaluation, with performance varying across methods. Generally, noisy spectra pose challenges for normalization methods that rely on limited reflectance values, while methods based on reflectance values across the entire spectrum (such as standard normal variate) perform better. The findings also suggest that absolute reflectance spectral measurements may be less effective for clinical diagnostics, whereas normalized spectral measurements are likely more appropriate. These findings provide a foundation for standardized performance testing of HSI-based medical devices, promoting the adoption of high-quality HSI technology for critical applications such as early cancer detection.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты