A Consensus to Revise the Minimum Speech Test Battery-Version 3.

Dunn Camille C, Zwolan Teresa A, Balkany Thomas J, Strader Heather L, Biever Allison, Gifford René H, Hall Melissa W, Holcomb Meredith A, Hill Heidi, King English R, Larky Jannine, Presley Regina, Reed Meaghan, Shapiro William H, Sydlowski Sarah A, Wolfe Jace

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The Minimum Speech Test Battery (MSTB) for adults was introduced in 1996 (Nilsson et al., 1996) and subsequently updated in 2011 (Advanced-Bionics et al., 2011). The MSTB has been widely used by clinicians as a guide for cochlear implant (CI) candidacy evaluations and to document post-operative speech recognition performance. Due to changes in candidacy over the past 10 years, a revision to the MSTB was needed.

METHOD: In 2022, the Institute for Cochlear Implant Training (ICIT) recruited a panel of expert CI audiologists to update and revise the MSTB. This panel utilized a modified Delphi consensus process to revise the test battery and to improve its applicability considering recent changes in CI care.

RESULTS

This resulted in the MTSB-Version 3 (MSTB-3), which includes test protocols for identifying not only traditional CI candidates but also possible candidates for electric-acoustic stimulation and patients with single-sided deafness and asymmetric hearing loss. The MSTB-3 provides information that supplements the earlier versions of the MSTB, such as recommendations of when to refer patients for a CI, recommended patient-reported outcome measures, considerations regarding the use of cognitive screeners, and sample report templates for clinical documentation of pre- and post-operative care. Electronic versions of test stimuli, along with all the materials described above, will be available to clinicians via the ICIT website (https://www.cochlearimplanttraining.com).

CONCLUSION

The goal of the MSTB-3 is to be an evidence-based test battery that will facilitate a streamlined standard of care for adult CI candidates and recipients that will be widely used by CI clinicians.

Для цитирования: Dunn Camille C, Zwolan Teresa A, Balkany Thomas J, Strader Heather L, Biever Allison, Gifford René H, Hall Melissa W, Holcomb Meredith A, Hill Heidi, King English R, Larky Jannine, Presley Regina, Reed Meaghan, Shapiro William H, Sydlowski Sarah A, Wolfe Jace. A Consensus to Revise the Minimum Speech Test Battery-Version 3.. American journal of audiology. 2024. DOI: 10.1044/2024_aja-24-00008.