MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/01455613231200762

Медицинская библиотека · Ear, nose, & throat journal · 2023

Development and Validation of a Nomogram to Predict the Risk of Tinnitus Severity in Patients With Unilateral Subjective Tinnitus.

Zhai Xiao-Min, Dong Jia-Jia, Zhang Hong-Lei, Yuan Jun, Hao Xue-Jing, Guo Rui

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

Purpose: To develop and validate a nomogram for predicting the risk of tinnitus severity in patients with unilateral subjective tinnitus.

Methods

The objective of this study was to establish and validate a nomogram specifically designed for patients with unilateral subjective tinnitus. We collected data on unilateral subjective tinnitus from the Air Force Medical Center, including 146 participants between January 2021 and June 2022. Risk factors for unilateral subjective tinnitus severity were evaluated by least absolute shrinkage and selection operator (LASSO) and binary logistic regression analysis. Internal verification was used to evaluate the performance of the nomogram. The discriminative ability was measured by the consistency index (C-indices) and the area under the curve (AUC) of the receiver operating characteristic (ROC) curves.

Results

All included patients were randomized according to a 7:3 ratio into the training cohort (104 patients) and the validation cohort (42 patients). The LASSO regression model identified sex, tinnitus loudness, and hearing loss as candidate variables. Binary logistic regression analysis showed that gender (OR: 0.76; 95% CI: 0.6-0.95; P = 0.021) and tinnitus loudness (OR: 1.37; 95% CI: 1.09-1.72; P = 0.009) were significant predictors of unilateral subjective tinnitus severity, while age, tinnitus matching frequency, and tinnitus duration were not. The significant predictors were included in the nomogram. Hearing loss was included in the nomogram based on prior clinical experience and previous studies. The training and validation cohorts C-indexes were 0.707 (95% CI: 0.607-0.806) and 0.706 (95% CI: 0.548-0.863), respectively. The training and validation cohort's AUC of the ROC curves were 0.692 and 0.705, respectively.

Conclusion

We have developed and validated a nomogram based on gender, hearing loss, and tinnitus loudness, which can effectively predict the risk of tinnitus severity in patients with unilateral subjective tinnitus. The nomogram provides personalized prediction results for patients with unilateral subjective tinnitus, which is beneficial for clinical decision-making and treatment plan development.

Для цитирования: Zhai Xiao-Min, Dong Jia-Jia, Zhang Hong-Lei, Yuan Jun, Hao Xue-Jing, Guo Rui. Development and Validation of a Nomogram to Predict the Risk of Tinnitus Severity in Patients With Unilateral Subjective Tinnitus.. Ear, nose, & throat journal. 2023. DOI: 10.1177/01455613231200762.