MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/23258160-20200228-04

Медицинская библиотека · Ophthalmic surgery, lasers & imaging retina · 2020

Quantifying Areas of Vascular Leakage in Sickle Cell Retinopathy Using Standard and Widefield Fluorescein Angiography.

Barbosa Joshua, Malbin Brett, Le Kim, Lin Xihui

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

To evaluate neovascular surface area change in sickle cell retinopathy following scatter photocoagulation treatment in wide- and standard-field fluorescein angiography (FA) scans using ImageJ software.

PATIENTS AND

METHODS

Images of 11 patients with wide- or standard-field FA scans pre- and post-treatment for sickle cell retinopathy were evaluated retrospectively by two graders using ImageJ. Graders traced lesions in the late arteriovenous phase and calculated the lesion area and intensity relative to the optic disc. Changes in area and intensity pre- to post-treatment were assessed using dependent t-tests.

RESULTS

Pre- to post-treatment, lesion area decreased by 3.34 ± 2.43 to 3.66 ± 3.72 disc areas (P < .001), whereas intensity decreased by 11.36 ± 25.87 to 22.97 ± 69.25 units (P = .104). Neovascular area declined status post-aphotocoagulation by 3.83 ± 3.65 disc areas (P = .003) for widefield images and by 2.81 ± 3.55 discs areas (P = .034) for standard fluorescein images. No statistical difference in area reduction was appreciated between imaging modalities (P = .652)

CONCLUSION

Neovascular area decreased significantly following scatter photocoagulation in both standard-field and widefield FA scans without an appreciable difference between imaging modalities. [Ophthalmic Surg Lasers Imaging Retina. 2020;51:153-158.].

Для цитирования: Barbosa Joshua, Malbin Brett, Le Kim, Lin Xihui. Quantifying Areas of Vascular Leakage in Sickle Cell Retinopathy Using Standard and Widefield Fluorescein Angiography.. Ophthalmic surgery, lasers & imaging retina. 2020. DOI: 10.3928/23258160-20200228-04.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.