MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mvr.2019.103958

Медицинская библиотека · Microvascular research · 2019

Effects of hemodialysis on blood volume, macro- and microvascular function.

Montero David, Haider Thomas, Nägele Matthias P, Barthelmes Jens, Cantatore Silviya, Sudano Isabella, Ruschitzka Frank, Bonani Marco, Flammer Andreas J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Vascular dysfunction is considered to spur the progression of cardiovascular disease in hemodialysis (HD) patients. Whether the HD procedure itself contributes to vascular dysfunction remains incompletely investigated. The present study sought to comprehensively assess the effects of HD on arterial and venous function along with concomitant changes in blood volume (BV).

METHODS AND

RESULTS

We determined BV with high-precision, automated carbon monoxide-rebreathing, arterial stiffness using applanation tonometry and intrinsic microvascular function via retinal vessel analysis prior to and after conventional 4-hour HD in fasting-controlled conditions in 10 patients. All HD patients were non-smokers and non-obese (body mass index = 22.8 ± 2.8 m·kg-2). Hypertension (70%), coronary artery disease (40%) and diabetes mellitus (20%) were the most prevalent comorbidities. Prior to HD, all patients presented with hypervolemia (+2208 ± 1213 ml). HD decreased body weight (-1.72 ± 1.25 kg, P = 0.002) and plasma volume (-689 ± 566 ml, P = 0.004), while hematocrit (Hct) was concomitantly increased (+4.8 ± 4.5%, P = 0.009). HD did not affect large elastic artery stiffness, as determined by carotid-femoral pulse wave velocity (P = 0.448) and carotid distensibility (P = 0.562). In contrast, flicker light-induced retinal venular dilation was reduced by three-fourths after HD (-2.4 ± 1.7%, P = 0.039), in parallel to increased retinal venular diameter (+11.2 ± 4.9 μm, P = 0.002). In regression analyses, a negative association was observed between HD-induced changes in Hct and retinal venular dilation (r ≥ -0.89, P ≤ 0.045).

CONCLUSION

Conventional HD resulting in substantial plasma volume removal do not alter large artery elastic properties, whereas intrinsic microvascular venular dilator function is markedly impaired, an effect directly associated with the increase in hemoconcentration.

Для цитирования: Montero David, Haider Thomas, Nägele Matthias P, Barthelmes Jens, Cantatore Silviya, Sudano Isabella, Ruschitzka Frank, Bonani Marco, Flammer Andreas J. Effects of hemodialysis on blood volume, macro- and microvascular function.. Microvascular research. 2019. DOI: 10.1016/j.mvr.2019.103958.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.