MedElevator Войти в исследования
← Поиск публикаций
Japanese journal of radiology · 2024

Contrast-enhanced thin-slice abdominal CT with super-resolution deep learning reconstruction technique: evaluation of image quality and visibility of anatomical structures.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nakamoto Atsushi, Onishi Hiromitsu, Ota Takashi, Honda Toru, Tsuboyama Takahiro, Fukui Hideyuki, Kiso Kengo, Matsumoto Shohei, Kaketaka Koki, Tanigaki Takumi, Terashima Kei, Enchi Yukihiro, Kawabata Shuichi, Nakasone Shinya, Tatsumi Mitsuaki, Tomiyama Noriyuki

Аннотация

PURPOSE: To compare image quality and visibility of anatomical structures on contrast-enhanced thin-slice abdominal CT images reconstructed using super-resolution deep learning reconstruction (SR-DLR), deep learning-based reconstruction (DLR), and hybrid iterative reconstruction (HIR) algorithms.

MATERIALS AND METHODS: This retrospective study included 54 consecutive patients who underwent contrast-enhanced abdominal CT. Thin-slice images (0.5 mm thickness) were reconstructed using SR-DLR, DLR, and HIR. Objective image noise and contrast-to-noise ratio (CNR) for liver parenchyma relative to muscle were assessed. Two radiologists independently graded image quality using a 5-point rating scale for image noise, sharpness, artifact/blur, and overall image quality. They also graded the visibility of small vessels, main pancreatic duct, ureters, adrenal glands, and right adrenal vein on a 5-point scale.

RESULTS: SR-DLR yielded significantly lower objective image noise and higher CNR than DLR and HIR (P < .001). The visual scores of SR-DLR for image noise, sharpness, and overall image quality were significantly higher than those of DLR and HIR for both readers (P < .001). Both readers scored significantly higher on SR-DLR than on HIR for visibility for all structures (P < .01), and at least one reader scored significantly higher on SR-DLR than on DLR for visibility for all structures (P < .05).

CONCLUSION: SR-DLR reduced image noise and improved image quality of thin-slice abdominal CT images compared to HIR and DLR. This technique is expected to enable further detailed evaluation of small structures.

Предметные рубрики MeSH