MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5137/1019-5149.jtn.33423-20.3

Медицинская библиотека · Turkish neurosurgery · 2022

Ruptured Proximal Anterior Cerebral Artery Aneurysm Treated with Flow Diverter.

Giorgianni Andrea, Vinacci Gabriele, Agosti Edoardo, Molinaro Stefano, Terrana Alberto Vito, Casagrande Federica, Vizzari Francesco Alberto, Baruzzi Fabio, Locatelli Davide

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

AIM: To discuss the use of flow modulation in treating ruptured aneurysms of the proximal segment of the anterior cerebral artery (A1 aneurysms). A1 aneurysms are rare, constituting approximately 1% of all intracranial aneurysms.

CASE REPORT: We report a left A1 aneurysm with a wide neck and small sac (3 × 1.8 mm). In order to treat the lesion, a flow diverter (4 × 12?18 mm, FRED, Microvention) was placed from M1 to the proximal end of the paraophthalmic internal carotid artery, without directly covering the neck of the aneurysm. No procedural bleeding occurred. During stent deployment, abciximab was infused. A day after the procedure, double antiplatelet therapy was initiated for 1 month, followed by single antiplatelet therapy for another 3 months. Due to the aneurysm morphology, we opted for a competitive flow diversion, covering the parent artery origin and leaving the A1A neck uncovered. A decreased flow into the aneurysmal parent artery gradually promoted aneurysm sac thrombosis. Both digital subtraction angiography at a 12-month follow-up and computed tomography angiography 24-month follow-up confirmed the regular patency of the stent and resolution of the aneurysm. In addition, the competitive modulation of flow in the ipsilateral anterior cerebral artery results in the narrowing of the vessel.

CONCLUSION

A1 aneurysm endovascular treatment is often challenging. Coiling or assisted coiling is the most frequently employed. Although flow diverter stent (FDS) is a consolidated technique for treating ruptured intracranial blister-like and dissecting aneurysms, its role in treating intracranial saccular ruptured aneurysms has to be elucidated. However, more number of case studies is needed to confirm the efficacy and safety of an FDS in treating ruptured A1 aneurysms.

Для цитирования: Giorgianni Andrea, Vinacci Gabriele, Agosti Edoardo, Molinaro Stefano, Terrana Alberto Vito, Casagrande Federica, Vizzari Francesco Alberto, Baruzzi Fabio, Locatelli Davide. Ruptured Proximal Anterior Cerebral Artery Aneurysm Treated with Flow Diverter.. Turkish neurosurgery. 2022. DOI: 10.5137/1019-5149.jtn.33423-20.3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.