Refining the role of presurgical PET/4D-CT in a large series of patients with primary hyperparathyroidism undergoing [18F]Fluorocholine PET/CT.

Kaseb Ashjan, Benider Houda, Treglia Giorgio, Cusumano Caterina, Bessac Darejan, Trimboli Pierpaolo, Vix Michel, Piccardo Arnoldo, Latgé Adrien, Imperiale Alessio

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

4D-CT has garnered attention as complementary imaging for patients with primary hyperparathyroidism (pHPT). Herein we evaluated a diagnostic strategy using [18F]Fluorocholine Positron Emission Tomography/Computed Tomography (PET/CT), followed by 4D-CT integrated into PET/4D-CT after negative/inconclusive PET/CT results in a single-center retrospective cohort of 166 pHPT patients who underwent parathyroidectomy after [18F]Fluorocholine PET/4D-CT.

METHODS

PET/CT and 4D-CT images were interpreted by three nuclear medicine physicians and one expert radiologist. Pathological findings were documented, and concordance rates were assessed. PET/CT results were categorized as positive/negative, with positive cases rated on a 3-level certitude scale: low, moderate, high. Inconclusive cases included low/moderate positivity. The added value of PET/4D-CT was assessed for negative/inconclusive cases through joint reading.

RESULTS

PET/CT lesion-based analysis showed almost perfect interobserver concordance (Cohen's kappa >.8). Across the cohort, PET/CT had a sensitivity of 83%, specificity of 97%, PPV of 90% and NPV of 94%. For 4D-CT, these values were sensitivity: 53%, specificity: 84%, PPV: 56% and NPV: 82%. PET/CT was significantly more accurate than 4D-CT. Among 44 patients with negative/inconclusive results, PET/CT had sensitivity: 60%, specificity: 91%, PPV: 71% and NPV: 86%. In the same patients, sensitivity and specificity of the sequential diagnostic algorithm increased to 80% and 97%, showing significantly better global accuracy (92% vs. 83%) than standard PET/CT.

CONCLUSIONS

We support a personalized imaging algorithm for pHPT, placing [18F]Fluorocholine PET/CT at the forefront, followed by 4D-CT integrated into PET/4D-CT in the same imaging session for negative/inconclusive results. When PET/CT results are clearly positive, the additional sensitivity benefit of 4D-CT is minimal.

Для цитирования: Kaseb Ashjan, Benider Houda, Treglia Giorgio, Cusumano Caterina, Bessac Darejan, Trimboli Pierpaolo, Vix Michel, Piccardo Arnoldo, Latgé Adrien, Imperiale Alessio. Refining the role of presurgical PET/4D-CT in a large series of patients with primary hyperparathyroidism undergoing [18F]Fluorocholine PET/CT.. European journal of clinical investigation. 2024. DOI: 10.1111/eci.14336.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.