MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/brainsci14121223

Медицинская библиотека · Brain sciences · 2024

Cerebrospinal Fluid Leak Prevention in Intradural Spine Surgery: A Long Series Analysis of Closure with Non-Penetrating Titanium Clips.

Anselmi Leonardo, Anania Carla Daniela, Ubezio Maria Cleofe, Farinaro Generoso, Creatura Donato, Ortolina Alessandro, Tomei Massimo, Baram Ali, Fornari Maurizio

СтатьяПеревод пока не подготовлен

Аннотация

Background/

Objectives

Postoperative cerebrospinal fluid (CSF) fistulas remain a significant concern in spinal neurosurgery, particularly following dural closure. The incidence of dural tears during spinal surgery is estimated between 1.6% and 10%. While direct suturing remains the gold standard, it has a failure rate of 5-10%. Various materials and techniques have been used to enhance dural closure. This study aims to assess the effectiveness of non-penetrating titanium clips (AnastoClip®) for dural closure in intradural spinal lesion surgeries.

Methods

A prospective analysis was conducted on 272 patients who were operated on for intradural spinal lesions from August 2017 to December 2023. Dural closure was performed using non-penetrating titanium clips with sealant, and, in select cases, autologous grafts. Postoperative care included early mobilization and routine MRI to assess outcomes. A comparative analysis was performed with a cohort of 81 patients treated with traditional sutures.

Results

Among the 272 patients, postoperative CSF leaks occurred in 32 cases (11.76%), requiring various management approaches. Thirteen cases required surgical revision, while others resolved with external lumbar drainage or fluid aspiration. Compared to the suture group, which had a fistula rate of 23.46%, the titanium clip group had a significantly lower fistula rate. Logistic regression analysis did not find statistically significant associations between fistula risk and clinical factors.

Conclusions

Non-penetrating titanium clips provide an effective alternative to sutures for dural closure, reducing CSF leak rates. They preserve dural integrity, reduce operative time, and avoid imaging artifacts, making them a viable advancement in spinal surgery with outcomes comparable to, or better than, traditional techniques.

Для цитирования: Anselmi Leonardo, Anania Carla Daniela, Ubezio Maria Cleofe, Farinaro Generoso, Creatura Donato, Ortolina Alessandro, Tomei Massimo, Baram Ali, Fornari Maurizio. Cerebrospinal Fluid Leak Prevention in Intradural Spine Surgery: A Long Series Analysis of Closure with Non-Penetrating Titanium Clips.. Brain sciences. 2024. DOI: 10.3390/brainsci14121223.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.