[A clinical study on reparation of orbital blowout fracture by bridge hydroxylapatite artificial bone].
Аннотация
OBJECTIVE
To explore a minimally invasive technique with hydroxylapatite artificial bone to repair the orbital blowout fracture.
METHODS
Twenty-one cases of orbital blowout fracture from March 2008 to April 2010 were enrolled. And the fractures were repaired with a bridge of hydroxylapatite artificial bone under a nasal endoscope. During a regular 6-month follow-up, anatomic and functional recovery was evaluated.
RESULTS
There was neither postoperative visual loss nor infection in all cases. At 3 months post-operation, diplopia vanished completely (n = 17), remained in peripheral vision (n = 2), existed in primary ocular position (n = 2) and the deviation of eyeball (n = 1). At Month 3, diplopia in peripheral vision or in primary position and the deviation of eyeball showed no improvement. Compared with the uninjured side, enophthalmos: ≤ 2 mm (n = 18), > 2 mm (n = 2) and > 4 mm (n = 1). The passive traction test was positive in one case. On computed tomograph (CT) scanning, there was no bone dislocation or slippage in all cases.
CONCLUSION
The surgical efficacy is excellent. The technique of combining the advantages of endoscopic sinus approach and hydroxyapatite artificial bone is worth a wider popularization.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.