The approach to placement of a continuous-flow intracorporeal ventricular assist device in small left ventricle.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

El-Andari Ryaan, Dion Josiane, Conway Jennifer, Pidborochynski Tara, Carter Lindsey, Singh Gurmeet, MacArthur Roderick, Meyer Steven, Jonker Devilliers, Freed Darren H, Buchholz Holger

Аннотация

BACKGROUND: The HeartMate 3 (HM3) has become among the most widely utilized durable left ventricular (LV) assist devices (LVAD) owing to reduced rates of pump thrombosis, bleeding, and stroke. One limitation of the HM3 is its large size, which poses a challenge for implantation in smaller LVs. Herein, we describe a novel technique for durable LVAD implantation in patients with a small LV.

METHODS: Patients who underwent durable LVAD implantation from January 2020 to August 2024 were included in this study. The modified technique involved excision of the mitral valve (MV) and associated apparatus to create room for the LVAD inflow. The primary outcome was mortality, and secondary outcomes included rates of postoperative complications and hemodynamic parameters. Patient follow-up was until September 2024.

RESULTS: Eleven patients were included in this study. All patients received an HM3. The median preoperative LV end-diastolic diameter was 5.1 cm. The median total time on LVAD was 149 days, and overall mortality was 27.2% occurring a median of 204 days post-LVAD implantation. Four patients (36.4%) underwent heart transplantation and 4 (36.4%) were alive on LVAD at last follow-up. Proportions of morbidity included readmission for heart failure (n = 2, 18.2%), cerebrovascular accident (n = 2, 18.2%), and pump thrombosis (n = 0).

CONCLUSIONS: The small LV has been a significant challenge for durable LVAD insertion and is often considered a contraindication. A modified approach to LVAD insertion, including excision of the MV and associated apparatus and alignment of the LVAD inflow cannula with the MV orifice, allows for LVAD implantation in patients with a small LV.