MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.178.3.1780623

Медицинская библиотека · AJR. American journal of roentgenology · 2002

Evaluation of abdominal aortic aneurysm after endoluminal treatment: comparison of color Doppler sonography with biphasic helical CT.

Golzarian Jafar, Murgo Salvatore, Dussaussois Luc, Guyot Sophie, Said Kamel Ait, Wautrecht Jean Claude, Struyven Julien

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of this study is to compare color Doppler sonography with biphasic helical CT in the evaluation of abdominal aortic aneurysms after endovascular repair.

MATERIALS AND

METHODS

Fifty-five patients prospectively underwent both color Doppler sonography and helical CT within 7 days after treatment by endovascular stent-graft. Aneurysmal thrombosis, the patency of the grafts, and the presence of a leak were evaluated in all patients. When a perigraft leak was observed, an attempt was made to identify its origin and outflow vessels. Helical CT was considered the gold standard technique.

RESULTS

Helical CT revealed aneurysmal thrombosis in 33 patients and a perigraft leak in 22 patients. In five patients, helical CT detected a small perigraft leak not shown by color Doppler sonography. In three patients with suboptimal examinations, color Doppler sonography revealed a suspected perigraft leak that was not confirmed by helical CT. In these eight patients, the perigraft leak was sealed or no longer observed during follow-up. Compared with enhanced helical CT, the sensitivity and specificity of color Doppler sonography for the diagnosis of a perigraft leak were 77% and 90%, respectively. In seven other patients, helical CT was superior to color Doppler sonography in detecting the origin of the perigraft leak and the outflow vessels. Two iliac artery dissections and one distal migration of the prosthesis were revealed only by helical CT.

CONCLUSION

Although color Doppler sonography may detect substantial perigraft leaks, helical CT is superior for detecting the origin of the perigraft leak, the outflow vessels, and the detection of complications related to the procedure.

Для цитирования: Golzarian Jafar, Murgo Salvatore, Dussaussois Luc, Guyot Sophie, Said Kamel Ait, Wautrecht Jean Claude, Struyven Julien. Evaluation of abdominal aortic aneurysm after endoluminal treatment: comparison of color Doppler sonography with biphasic helical CT.. AJR. American journal of roentgenology. 2002. DOI: 10.2214/ajr.178.3.1780623.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.