Ozdemir Baser Ozden, Koseoglu Derya, Cetin Zeynep, Catak Merve, Berker Dilek

Аннотация

OBJECTIVE: We aimed to find and compare the efficacy of ultrasonography (US), technetium-99m methoxyisobutylisonitrile parathyroid scintigraphy (MIBI-S), and single-photon emission computed tomography-computed tomography (SPECT-CT) in detecting the localization of parathyroid adenomas in patients with primary hyperparathyroidism.

METHODS: In total, 348 patients were included in this study. Preoperative parathyroid imaging with US, MIBI-S, and SPECT-CT was evaluated and compared with operative findings. The results of the imaging methods were compared with pathology and operation reports.

RESULTS: In 318 patients (91.3%), one of the imaging methods was able to localize the lesion correctly. US detected the localization of the parathyroid lesions correctly in 268 patients (77%), whereas SPECT-CT and MIBI-S were correct in 254 (73%) and 209 (60%) patients, respectively. There was a statistically significant relationship between the parathyroid hormone (PTH) level and 3 imaging methods' success rates (P < .05). The PTH cut-off value, which best determined the correct localization, was 152.5 pg/mL for US, 143 pg/mL for MIBI-S, and 143 pg/mL for SPECT-CT. It was observed that the correct localization rate for parathyroid lesions increased with higher PTH levels.

CONCLUSION: In our study population, US was more successful, in most cases, than other imaging methods in localizing parathyroid lesions but SPECT-CT was more accurate in localizing mediastinal lesions. In addition, it was found that preoperative PTH levels affect the accuracy of imaging methods.