Comparison of the diagnostic accuracy of 18F-Fluorocholine PET and 11C-Methionine PET for parathyroid localization in primary hyperparathyroidism: a systematic review and meta-analysis.

Bioletto Fabio, Barale Marco, Parasiliti-Caprino Mirko, Prencipe Nunzia, Berton Alessandro Maria, Procopio Massimo, Deandreis Désirée, Ghigo Ezio

Сравнительное исследованиеСтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Primary hyperparathyroidism is characterized by an autonomous hypersecretion of parathyroid hormone by one or more parathyroid glands. Preoperative localization of the affected gland(s) is of key importance in order to allow minimally invasive surgery. At the moment, 11C-Methionine and 18F-Fluorocholine PET studies appear to be among the most promising second-line localization techniques; their comparative diagnostic performance, however, is still unknown.

METHODS

PubMed/Medline and Embase databases were searched up to October 2020 for studies estimating the diagnostic accuracy of 11C-Methionine PET or 18F-Fluorocholine PET for parathyroid localization in patients with primary hyperparathyroidism. Pooled sensitivity and positive predictive value were calculated for each tracer on a 'per-lesion' basis and compared using a random-effect model subgroup analysis.

RESULTS

In total, 22Twenty-two studies were finally considered in the meta-analysis. Of these, 8 evaluated the diagnostic accuracy of 11C-Methionine and 14 that of 18F-Fluorocholine. No study directly comparing the two tracers was found. The pooled sensitivity of 18F-Fluorocholine was higher than that of 11C-Methionine (92% vs 80%, P < 0.01), while the positive predictive value was similar (94% vs 95%, P = 0.99). These findings were confirmed in multivariable meta-regression models, demonstrating their apparent independence from other possible predictors or confounders at a study level.

CONCLUSION

This was the first meta-analysis that specifically compared the diagnostic accuracy of 11C-Methionine and 18F-Fluorocholine PET for parathyroid localization in patients with primary hyperparathyroidism. Our results suggested a superior performance of 18F-Fluorocholine in terms of sensitivity, while the two tracers had comparable accuracy in terms of positive predictive value.

Для цитирования: Bioletto Fabio, Barale Marco, Parasiliti-Caprino Mirko, Prencipe Nunzia, Berton Alessandro Maria, Procopio Massimo, Deandreis Désirée, Ghigo Ezio. Comparison of the diagnostic accuracy of 18F-Fluorocholine PET and 11C-Methionine PET for parathyroid localization in primary hyperparathyroidism: a systematic review and meta-analysis.. European journal of endocrinology. 2021. DOI: 10.1530/eje-21-0038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.