m+Medelevator.RU
← Поиск публикаций
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2020

Duplex Ultrasound Investigation for the Detection of Obstructed Iliocaval Venous Stents.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sebastian Tim, Barco Stefano, Engelberger Rolf P, Spirk David, Schindewolf Marc, Baumann Frederic, Baumgartner Iris, Kucher Nils

Аннотация

OBJECTIVE: Duplex ultrasound (DUS) is used for routine surveillance of stents in iliocaval veins, but direct visualisation is often challenging. Duplex ultrasound criteria for detecting venous stent obstruction (VSO) have not been defined to date.

METHODS: A nested case control study of 120 patients (42 ± 17 years, 53% women, mean 2.7 ± 1.8 stents) was performed, and the performance of various duplex parameters for detecting VSO (defined as > 50% lumen diameter reduction or occlusion) was tested, confirmed by biplane venography or intravascular ultrasound (IVUS). Forty patients with VSO (25 with stent occlusion, 15 with >50% in stent stenosis) were matched to 80 control patients by age, gender and index diagnosis who fulfilled the following criteria: (1) ongoing symptom control (Villalta score < 5), (2) good image quality of entire stent segment, (3) spontaneous colour Doppler signal > 50% of lumen in entire stent segment, (4) at least two DUS where the baseline DUS was obtained within 24 h after successful venous intervention.

RESULTS: The best test was the combination of peak flow velocity and flow pattern analysis at the stent inlet. A peak flow velocity >10 cm/s and a flow pattern spontaneously modulated by respiration ruled out VSO with a specificity of 93.7% (95% CI 86.0%-97.3%). A peak flow velocity ≤10 cm/s or any Doppler flow pattern other than spontaneously modulated by respiration was 92.1% (95% CI 79.2%-97.3%) sensitive to detect VSO.

CONCLUSION: The combination of peak flow velocity and analysis of Doppler flow pattern at the stent inlet is accurate to diagnose or rule out stent occlusion. Indirect criteria should always be combined with direct visualisation of iliocaval stents since those may be less sensitive for detecting stent stenosis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты