OBJECTIVE

Medialization laryngoplasty is commonly used to treat glottic insufficiency. In this study, we investigated the effects of implant stiffness (Young modulus), medialization depth, and implant medial surface shape on acoustic outcomes.

STUDY

DESIGN

Basic science study using ex vivo laryngeal phonation model.

METHODS

In an ex vivo human larynx phonation model, bilateral medialization laryngoplasties were performed with implants of varying stiffness, medial surface shape (rectangular, divergent, and convergent), and varying depths of medialization. The subglottal pressure, the flow rate, and the outside sound were measured as the implant parameters were varied.

RESULTS

Medialization through the use of implants generally improved the harmonic-to-noise ratio (HNR) and the number of harmonics excited in the outside sound spectra. The degree of acoustic improvement depended on the implant insertion depth, stiffness, and to a lesser degree implant shape. Varying implant insertion depth led to large variations in phonation for stiff implants, but had much smaller effects for soft implants.

CONCLUSIONS

Implants with stiffness comparable to vocal folds provided more consistent improvement in acoustic outcomes across different implant conditions. Further investigations are required to better understand the underlying mechanisms.

Для цитирования: Zhang Zhaoyan, Chhetri Dinesh K, Bergeron Jennifer L. Effects of implant stiffness, shape, and medialization depth on the acoustic outcomes of medialization laryngoplasty.. Journal of voice : official journal of the Voice Foundation. 2014. DOI: 10.1016/j.jvoice.2014.07.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.