MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40729-024-00542-1

Медицинская библиотека · International journal of implant dentistry · 2024

The comparison of visibility of the maxillary sinus septa between cone-beam computed tomography scans and panoramic radiograph images as dependent on the cortical bone thickness: a retrospective comparative study.

Ketabi Ali Reza, Hassfeld Stefan, Lauer Hans-Christoph, Piwowarczyk Andree

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze the visibility of the maxillary sinus septa (MSS) in panoramic radiography (PR) versus cone beam computed tomography (CBCT) and to investigate whether the buccal cortical bone thickness (BT) or the septa dimensions influence their visibility.

METHODS

Corresponding PR and CBCT images of 355 patients were selected and examined for MSS visibility. The septa dimensions (width, height, depth) and the BT were measured. Results were analysed statistically.

RESULTS

Comparing the corresponding regions on CBCT and PR, 170 MSS were identified; however, only 106 of these were also visible using PR. The MSS visibility was significantly higher on CBCT versus PR images (P1: p = 0.039, P2: p = 0.015, M1: p = 0.041, M2: p = 0.017, M3: p = 0.000), except region C (p = 0.625). Regarding the measurements of MSS dimensions, only the height in region M1 (p = 0.013) and the width in region P2 (p = 0.034) were significantly more visible on CBCT. The BT in the area of the MSS was found to have a marginal influence on its visibility on the PR images only in regions M3 and M1 (M3: p = 0.043, M1: p = 0.047). In terms of MSS visibility based on the dimensions, significance was found for all three influencing variables only in region P2 (width; p = 0.041, height; p = 0.001, depth; p = 0.007). There were only isolated cases of further significance: M3 for width (p = 0.043), M2 for height (p = 0.024), and P1 for depth (p = 0.034), no further significance was noted.

CONCLUSION

MSS visibility appears significantly higher on CBCT versus PR images. It is concluded that the septa dimensions and BT can influence MSS visibility on PR images just in certain regions.

Для цитирования: Ketabi Ali Reza, Hassfeld Stefan, Lauer Hans-Christoph, Piwowarczyk Andree. The comparison of visibility of the maxillary sinus septa between cone-beam computed tomography scans and panoramic radiograph images as dependent on the cortical bone thickness: a retrospective comparative study.. International journal of implant dentistry. 2024. DOI: 10.1186/s40729-024-00542-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.