Influence of Biometric Data on Planning Strabismus Surgery.

Hirnschall Nino, Malek Katharina, Kaltofen Thomas, Priglinger Siegfried, Priglinger Siegmund, Harrer Annette, Findl Oliver, Partik Gerhard

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the influence of optical biometry data (axial eye length, anterior chamber depth) on planning strabismus surgery using a simulation software and partial least squares regression.

METHODS

This retrospective study included patients who had undergone strabismus surgery in one eye involving only the horizontal eye muscles. Furthermore, optical biometry had been performed and the extent of strabismus had been measured pre- and postoperatively. In the next step the strabismus surgery was simulated (See++, RISC, Austria) with and without axial eye length data. In the last step, anatomical data of the eye were used and their influence on the postoperative extent of strabismus was evaluated using partial least squares regression and boot strapping.

RESULTS

Of 97 patients, 92 were included in the analysis. In all cases the extent of strabismus was reduced by at least 25% and in 60% of the cases the reduction was at least 75%. Taking the axial eye length into account improved the simulation slightly (change of surgical planning: 0.30 mm, standard deviation 1.65 mm).

DISCUSSION: The simulation model used showed that including the axial eye length is useful for strabismus surgery planning. However, the anterior chamber depth/axial eye length was found to have a significantly greater impact.

Для цитирования: Hirnschall Nino, Malek Katharina, Kaltofen Thomas, Priglinger Siegfried, Priglinger Siegmund, Harrer Annette, Findl Oliver, Partik Gerhard. Influence of Biometric Data on Planning Strabismus Surgery.. Klinische Monatsblatter fur Augenheilkunde. 2022. DOI: 10.1055/a-1699-2679.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.