m+Medelevator.RU
← Поиск публикаций
American journal of ophthalmology · 2020

Comparison of Methods for Measuring Cyclodeviation.

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Liebermann Laura, Hatt Sarah R, Leske David A, Klaehn Lindsay D, Kramer Andrea M, Holmes Jonathan M

Аннотация

PURPOSE: To compare the double-Maddox rod test with other methods of measuring cyclodeviation DESIGN: Retrospective cohort study.

METHODS: We retrospectively identified 153 adults in a clinical practice with cyclodeviation assessed using double-Maddox rods, of whom 105 were also assessed using fusible synoptophore targets, 73 using nonfusible synoptophore targets, 118 using single-Maddox rod, and 43 using fundus photography. Relationships between double-Maddox rod and other tests were evaluated by calculating mean differences with 95% confidence intervals (CI), intraclass correlation coefficients (ICC), and Bland-Altman plots with linear regression.

RESULTS: Synoptophore cross-in-circle targets and the largest (of right or left) single-Maddox rod values were similar to double-Maddox values (mean differences: -1.2° and 0.1°, respectively; ICC: 0.79 and 0.82, respectively). Synoptophore house targets measured less excyclodeviation (mean difference: -2.7°; ICC: 0.71). Mean summed single-Maddox rod values were somewhat similar to double-Maddox values (mean difference: 1.5°; ICC: 0.85), but differences increased with greater cyclodeviation (r2 = 0.2678; P < .001). Fundus photographs showed large, uncorrelated differences compared with double-Maddox rod test, when summing right and left eyes and when using the largest of right or left (mean differences: 12.2° and 6.2°; ICC: -0.02 and 0.21, respectively), and differences increased with greater cyclodeviation (r2 = 0.4094; P < .001 and r2 = .1143; P= .03, respectively).

CONCLUSIONS: There was good agreement between double-Maddox and the largest single- Maddox test values and synoptophore cross-in-circle targets but poorer agreement with other tests. Further study is needed to understand which measurements best reflect true cyclodeviation and relationships with symptoms.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты